摘要 某炼油厂催化裂化装置油浆蒸汽发生器使用10 a后,为保障平稳生产,用同一厂家生产的同型号设备进行了更换,新设备投用仅18个月,管束即发生穿孔泄漏,对装置生产造成了较大影响。通过对油浆蒸汽发生器工艺流程、设备结构、运行工况、腐蚀状况和腐蚀产物进行检查分析,确认空泡腐蚀是导致管束快速穿孔泄漏的主要原因。通过对设备运行控制和介质检测数据等相关资料对比关联,确定了换热管外壁无盐水侧空泡腐蚀发生的原因,并提出针对性的预防和改进措施。 In order to ensure smooth production of a catalytic cracking unit,slurry steam generator was replaced with a same one after 10 year utilization. However,leakage at tube bundle was found in 18 months which brought adverse impact for production.Cavitation corrosion was confirmed to be the main reason through investigation on process flow,equipment structure,operating conditions,corrosion status, material testing and corrosion products. Based on comparison between equipment operation controlling and media testing data,cause of cavitation erosion on the external tube wall was found,and improvement measures were proposed accordingly.
出处 《石油化工腐蚀与防护》 CAS 2017年第3期51-55,共5页 Corrosion & Protection In Petrochemical Industry
关键词 运行控制 结垢堵塞 空泡腐蚀 防控措施 operation controlling fouling and blockage cavitation corrosion prevention measures
  • 相关文献

参考文献4

二级参考文献7

  • 1王志高.非金属抗磨蚀保护层的应用和效益[J].陕西水力发电,1993,9(1):23-29. 被引量:4
  • 2刘正义.机械装备失效分析图谱[M].广州:广东科技出版社,1990..
  • 3[4][美]金属手册(第8版)第10卷(中译本)[M].
  • 4[3]机械工业部科技与质量监督司,中国机械工程学会理化检验分会.机械工程材料测试手册:物理金相卷[M].沈阳:辽宁科学技术出版社,2002:135.
  • 5卢绮敏.石油工业中的腐蚀与防护[M].北京:化学工业出版社,2001.10.
  • 6王家骐.胡湘诚.宋兴诚.黄书泽.台色冶炼,2003.32(2):36.
  • 7杨庆,张建民,戴光清,王海云.空化形成机理和比尺效应[J].水力发电,2004,30(4):56-59. 被引量:18