期刊文献+

蜡油加氢装置高压换热器内漏分析及处理

Analysis and Treatment of Internal Leakage of High Pressure Heat Exchanger in VGO Hydrogenation Unit
下载PDF
导出
摘要 介绍了某公司2.1 Mt/a蜡油加氢裂化装置高压螺纹锁紧环换热器1110-E01006在投料试车催化剂预硫化阶段发生的管束内漏事故,从换热器管箱结构特点、工艺流程、查漏裂纹形态及特征等多方面,综合分析了该换热器内漏的原因,并提出了相应的处理措施和建议。 Internal leakage of a tube bundle occurred in the stage of catalyst prevulcanization. The tube bundle was located in1110-E01006 heat exchanger of 2. 1 Mt/a VGO hydrocracking unit. Comprehensive analysis of the internal accident was made in several aspects,such as structural characteristics of heat exchanger,process and cracking,and then corresponding measures and suggestions were offered accordingly.
作者 张辉
出处 《石油化工腐蚀与防护》 CAS 2017年第3期60-63,共4页 Corrosion & Protection In Petrochemical Industry
关键词 加氢裂化 螺纹锁紧环换热器 裂纹修复 应力腐蚀开裂 hydrocracking thread locking ring heat exchanger crack reeovery stress corrosicn cracking