摘要
对一台220kV油浸式变压器,进行了变压器油箱的振动及噪声测试。通过对测试数据的时域分析和频域分析,给出了大型电力变压器的声振特性及传播规律。
For a 220kV oil-immersed transformer, the vibration and noise of the trans- former tank are tested. Through the time and frequency domain analysis of the test da- ta, the sound and vibration characteristics and propagation law of the large power transformer are presented.
作者
马裕超
莫娟
徐铼
樊宝珍
徐金
恽毅
MA Yu-chao MO Juan XU Lai(,China Electric Power Research 2.State Grid Jiangsu Electric Power 3. Shanghai Advanced Research FAN Bao-zhen1, XU Jin~,YUN Yi3 Institute, Beijing 100055, China Corporation, Nanjing 210024, China Sciences, Shangha nstitute, Chinese Academy of 201210, Chin)
出处
《变压器》
北大核心
2017年第7期49-55,共7页
Transformer
基金
国家电网公司科技项目(GC71-14-047)
关键词
油浸式变压器
振动
噪声
光纤测试
Oil-immersed transformer
Vibration
Noise
Optical fiber test