期刊文献+

应用激光鞘拔除电极导线的初步临床经验 被引量:2

Initial experience using excimer laser for the extraction of implanted pacemaker and implantable cardioverter defibrillator leads
原文传递
导出
摘要 目的报道应用激光鞘经静脉电极导线拔除的初步临床经验。方法回顾性分析2015年9月至2017年4月就诊于北京大学人民医院,应用准分子激光鞘拔除电极导线患者的临床资料。结果 35例患者应用激光鞘技术拔除电极导线,年龄(63.4±17.1)岁,其中男性27例(77.1%),共拔除电极导线77根,平均植入年限10(4~26)年,其中除颤电极导线13根(16.9%)。拔除原因分别为囊袋感染25例(71.4%),电极故障5例(14.3%),菌血症3例(8.6%),感染性心内膜炎2例(5.7%)。应用激光鞘电极导线拔除手术完全成功率为97.1%,临床成功率为100%,无一例发生死亡及外科干预的主要并发症。结论准分子激光鞘电极导线拔除起搏及除颤电极导线安全、有效、可提高手术效率。 Objective The present study reports the initial experience using this novel technique to extract implan- ted pacemaker and implantable cardioverter defibrillator (ICD) leads. Methods We performed a retrospective study of consecutive patients undergoing lead extraction using the laser sheath in a single center, from September 2015 to April 2017. Basic clinical data of patients and lead characteristics, indications,and outcomes were analyzed. Results A total of 77 leads, including 13I CD leads, were removed using the laser sheath from 35 patients (age 63.4!17.1 years;27 male, 71.4%). The median implantation duration was }0 years(range 4-26 years). Indications were infection (n = 30), leads fracture (n = 5).The femoral approach was used in combination with the laser tech- nique in one case. The Evolution sheath was used in combination with the laser technique in one case.Complete pro cedural success was achieved with 34 patients (97.1%). Although the electrode tip was left behind in the remaining one lead, the desired clinical outcomes could be achieved; which were defined as clinical success. No case resulted in failure. There were no major complications, including death and bleeding requiring open-chest surgery. Conclusions Laser sheaths appear to provide a feasible and effective means of extracting implanted pacemaker and ICD leads.
出处 《中国心脏起搏与心电生理杂志》 2017年第3期204-209,共6页 Chinese Journal of Cardiac Pacing and Electrophysiology
基金 北京大学人民医院研究与发展基金(项目编号:RDY2016-02)
关键词 心血管病学 植入装置感染 电极导线 拔除 准分子激光鞘 Cardiology Infection of implanted device Lead Extraction Laser sheath
  • 相关文献

参考文献1

二级参考文献6

  • 1Maytin M, Epstein LM. The challenges of transvenous lead extraction [J]. Heart,2011,97:425.
  • 2Wazni OL, Epstein LM, Wilkoff BL, et al. Lead extraction in the contemporary setting : the lexicon study : an observational retrospective study of consecutive laser lead extractions[ J] . J Am Coll Cardi-ol ,2010 ,55 :579.
  • 3Kennergren C, Bucknall CA, Butter C,et al. Laser-assisted lead extraction :the European experience [ J ]. Europace, 2007 ,9 :651.
  • 4Bordachar P, Defaye P, Peyrouse E,et al. Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach [J]. Circ Arrhythm Electrophysiol, 2010,3:319.
  • 5Epstein LM, Love CJ , Wilkoff BL, et al. Superior vena cava defibrillator coils make transvenous lead extraction more challenging and riskier[ J] . J Am Coll Cardiol ,2013 ,61 :987.
  • 6李延辉,李剑明.激光导管拔除心脏起搏除颤导线的临床应用研究[J].中华心血管病杂志,2011,39(4):363-368. 被引量:4

共引文献2

同被引文献12

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部