期刊文献+

超声引导颈内静脉置管术对肿瘤患者导管相关性感染的影响 被引量:3

Effect of ultrasound-guided internal jugular vein catheterization on catheter-related infection in cancer patients
原文传递
导出
摘要 目的探讨超声引导下行颈内静脉精确置管的优势及其对肿瘤患者导管相关性感染的影响。方法将2014年1月-2015年12月的346例实施颈内静脉穿刺置管术的住院肿瘤患者随机分为对照组和超声组,分别采用盲穿法和超声引导下进行颈内静脉置管操作,比较2组一次穿刺成功率、总成功率、平均完成置管操作的时间、导管相关性感染发生率以及平均导管留置时间。结果对照组与超声组一次穿刺成功率分别为87.3%和97.7%,总成功率分别为96.5%和100%,平均完成置管操作的时间分别为(9.62±2.33)min和(8.48±1.45)min,导管相关性感染率分别9.6%和3.5%,差异均有统计学意义(P<0.05)。结论超声引导颈内静脉精确置管能有效提高穿刺成功率,减少肿瘤患者导管相关性感染的发生。 Objective To investigate ultrasound-guided internal jugular vein accurate catheterization to prevent catheter-related infections in cancer patients. Methods A prospective study was selected in hospitalized cancer patients who receive internal jugular vein catheterization from January 2014 to December 2015. 346 cases were randomly divided into ultrasound and control group,the control group receive blind method internal jugular vein catheterization,ultrasound group receive ultrasound-guided internal jugular vein catheterization. The success rate of first puncture,the total success rate,the mean operating time,the mean retention time and the rate of catheter-related infections were compared. Results The success rate of first puncture of contrl group and ultrasound group were 87. 3% and 97. 7% respectively. The mean operating time of contrl group and ultrasound group were( 9. 62 ± 2. 33) min and( 8. 48 ± 1. 45) min,the rate of catheter-related infections of contrl group and ultrasound group were 9. 6% and 3. 5%,all the difference were statistically significant( P〈0. 05). Conclusion Ultrasound-guided internal jugular vein accurate catheterization can effectively improve the puncture success rate and reduce catheter-related infections in cancer patients.
出处 《中国消毒学杂志》 北大核心 2017年第6期531-533,共3页 Chinese Journal of Disinfection
基金 浙江省自然科学基金(LY16G020016)
关键词 颈内静脉置管 超声引导 导管相关性感染 internal jugular vein catheterization ultrasound-guided catheter-related infections
  • 相关文献

参考文献8

二级参考文献65

  • 1袁芳,刘映红,李铮,朱建玲,曹丹鸣,李一宁.超声引导下颈内静脉留置永久性双腔导管在维持性血液透析患者中的应用[J].中南大学学报(医学版),2014,39(1):61-66. 被引量:19
  • 2程莉,刘国安.颈内静脉置管失败的原因与对策[J].东南国防医药,2007,9(1):35-36. 被引量:6
  • 3Forestier F,Rossi H,Calderon J,et al.Training for adult subclavian venous catheterization:use of real-time echography[J].Ann Fr Anesth Reanim,2002,21(9):698-702.
  • 4Sofocleous CT,Schur I,Cooper SG,et al.Sonographically guided placement of peripherally inserted central venous catheters:review of 355 procedures[J].Am J Roentgenol,1998,170:1613-1616.
  • 5杭燕南,庄新良,蒋豪,等.当代麻醉学.上海:上海科技出版社,2003:987-989.
  • 6Randolph AG,Cook DJ,Gonzales CA,et al.Ultrasound guidance for placement of central venous catheters:a meta-analysis of the literature.Cnt Care Med,1996,24(12):2053-2058.
  • 7Hind D,Calvert N,MeWilliams R,et al.Ultrasounic locating devices for central venous cannulation:meta-analysis.BMJ,2003,327(7411):361.
  • 8Maury E,Guglielminotti J,Alzieu M,et al.Ultrasonic exzamination; an altermative to chest radiography after central venous catheter insertion? Am J Respir Crit Care Med,2001,164(3):403-405.
  • 9Aikaterini T,Athina A,Joseph,et al.Incidence and risk factors for central vascular catheter-related bloodstream infection in a teritiary care hospital[J].New Microbiologica,2012,35(6):429-437.
  • 10Emilpaolo M,Nauro N,Luciana F,et al.Deep impact of ultrasound in the intensive care unit:the ICU sound protocol[J].Anesthesiology,2012,177(4):801-809.

共引文献454

同被引文献21

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部