摘要 目的探讨容积旋转调强技术(VMAT)应用于全身放疗(TBI)的剂量学特点,为临床应用提供技术参考。方法选取2012年8月至2015年1月于南京明基医院接受包含TBI清髓预处理方案的恶性血液系统疾病患者15例,采用瓦里安Eclipse 10.0计划系统,单弧360°多中心衔接的方法制定VMAT计划,处方剂量12 Gy/6f。通过分析剂量体积直方图(DVH)曲线,评估靶区、危及器官的剂量分布;通过估计治疗计划的总机器跳数、出束时间以及总治疗时间来评估计划的实施效率;最后采用Matrix X二维电离室矩阵进行剂量验证。结果 15例患者TBI计划的平均总机器跳数为(2308±210.7)MU,剂量率约400 c Gy/min,计划平均实施时间为30 min。靶区平均剂量(Dmean)为(12.58±0.45)Gy,最小剂量(Dmin)为(11.27±0.13)Gy,最大剂量(Dmax)为(15.35±0.65)Gy,并且危及器官受量较低。结论在TBI治疗中,运用VMAT技术可以获得良好的靶区剂量均匀性及计划实施效率,同时正常组织受量较低,因此有着较好的临床应用价值。 Objective To investigate the feasibility and dosimetry characteristics of a volumetric arc therapy (VMAT) technique for total body irradiation (TBI). Methods VMAT technique was performed for fifteen patients receiving TBI therapy as a preconditioning regimen of hemapoietic stem cell transplantation at BenQ Medical Center, between Augnst,2012 and January, 2015. Eclipse 10. 0 Treatment Planning system was employed to perform treatment plan. The VMAT p/an consisted of three centers : the head and neck, the chest and the pelvis( each with a 360~ arcs). The prescription dose was 12 Gy/6 f. The homogeneity of planning target volume (PTV) and organs at risk (OAR) were measured by dose volume histograms (DVH) curve. Monitor units (MU), the bean time and total treatment time were prescribed to ensure the efficiency of the VMAT planning. Finally, the 2D ionization chamber array Matrix X was used to verify the VMAT treatment. Results In all patients, there were average MUs of (2308±210. 7)MU, and dose rate of 400 cGy/min. The total treatment delivery time was approximately 30 min. Using this technique, the average median dose for PTV was ( 12. 58±0. 45 ) Gy, with a range of( 11.27 -± 0. 13 ) Gy to ( 5.35 ±0. 65 ) Gy. Simultaneously, a considerable OAR dose reduction of 14. 9% N 61.9% was observed by using this planning. Conclusion VMAT technique could obtain dose conformality of PTV, reduce the dose of OAR, and improve the treatment delivery efficiency. And it is expected to facilitate the clinical transition of TBI for the patients with hematologic malignancies.
出处 《临床肿瘤学杂志》 CAS 2017年第6期544-547,共4页 Chinese Clinical Oncology
关键词 造血干细胞移植 全身放疗技术 容积旋转调强技术 剂量体积直方图 Hemapoietic stem cell transplantation Total body irradiation (TBI) Volume modulated arc therapy (VMAT) Dose volume histograms
  • 相关文献

参考文献1

二级参考文献16

  • 1Harousseau JL.Multiple myeloma in the elderly : when to treat,when to go to transplant[J]. Oncologg, 2010,24(11) : 992-998.
  • 2Burnett A, Wetzler M, Lowenberg B. Therapeutic advances in acute myeloid leukemia[J].J Clin Oncol, 2011,29(5) :487-494.
  • 3McCutchen KW,Watkins JM,Eberts P,et al. Helical tomotherapy for total lymphoid irradiation[J]. Radiat Med, 2008,26(10): 622-626.
  • 4Schultheiss TE,Wong J,Liu A,et al.Image- guided total marrow and total lymphatic irradiation using helical tomotherapy[J].Int J Radiat Oncol Biol Phys,2007,67(4).1259- 1267.
  • 5Wong JY,Liu A,Schultheiss T,et al.Targeted total marrow irradiation using three-dimensional image-guided tomographic intensity-modulated radiation therapy:an alternative to standard total body irradiation[J].Biol Blood Marrow Transplant, 2006,12(3): 306-315.
  • 6Clift RA,Buckner CD,Appelbaum FR,et al.Allogeneic marrow transplantation in patients with acute myeloid leukemia in first remission..a randomized trial of two irradiation regimens[J]. Blood, 1990,76(9) : 1867-1871.
  • 7Clift RA,Buckner CD,Appelbaum FR,et al. Allogeneic marrow transplantation in patients with chronic myeloid leukemia in the chronic phase:a randomized trial of two irradiation regimens[J]. Blood, 1991,77(8): 1660-1665.
  • 8Schenken LL,Hagemann RF.Time/dose relationships in experimental radiation cataractogenesis[J]. Radiology, 1975,117(1) : 193-198.
  • 9Socie G, Clift RA,Blaise D,et al.Busulfan plus cyclophosphamide compared with total- body irradiation plus cyclophosphamide before marrow transplantation for myeloid leukemia.Long-term follow-up of 4 randomized studies[J]. Blood, 2001,98(13). 3569-3574.
  • 10Della Volpe A,Ferreri AJ,Annaloro C,et al. Lethal pulmonary complications significantly correlate with individually assessed mean lung dose in patients with hematologic malignancies treated with total body irradiation[J].Int J Radiat Oncol Biol Phys, 2002,52(2) :483-488.

共引文献3

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部