摘要
结合巴厘岛电厂~#2发电机转子出水支座处甩水问题的处理,分析了引起双水内冷发电机转子甩水的原因,进行了相应的改进工作,总结了处理经验,可为类似改进提供借鉴。
Based on the treatment of Bali Power Plant generator No. 2 rotor discharging support water splash,the cause of water splash was analyzed. Improvement was carried out. Experience was summarized,which could be referred by similar projects.
出处
《华电技术》
CAS
2017年第7期44-45,共2页
HUADIAN TECHNOLOGY
关键词
巴厘岛
双水内冷
发电机转子
甩水
Bali
dual internal water-cooled
generator rotor
splash water