风管式空调内机水泵噪音产生机理分析与优化 被引量:2

Mechanism Analysis and Optimization of Noise Caused by Water Pumpof Duct Indoor Unit of Air Conditioner
下载PDF
导出
摘要 风管式空调水泵噪音主要是100Hz电磁噪音,是由水泵电机振动通过水泵支架传递到外壳钣金并通过外壳钣金向外辐射产生的。根据噪音产生的机理及目前水泵结构缺陷分析结果,优化设计一种新的水泵隔振胶垫,有效降低了水泵噪音。 The noise caused by water pump withinduct indoor unit of air conditioner is mainly 100 Hz electromagnetic type, which originates from the motor vibration and then transfer to the sheet metal of the cabinet through bump support and radiated by the sheet metal. Basis on the analysis of the noise generation mechanism and the drawbacks of the present bump structure, a new type of rubber vibration-isolation pad is designed, and in consequence the noise is reduced effectively.
出处 《电子测试》 2017年第7期44-45,43,共3页 Electronic Test
关键词 风管式空调 水泵噪音 噪音源定位 噪音辐射 隔振胶垫 duct air conditioner water-bump noise noise source identification noise radiation rubber vibration-isolation pad