对秦山核电基地烟囱流出物的粒径分布谱进行了实验测量,结果表明:气态流出物中的气溶胶粒径大多在1μm以下,但总粒子数浓度随机组类型不同而不同。测量结果为评估核电厂气态流出物监测系统采样的有效性提供了参考。
Particle size distribution measurement of gaseous effluents from Qinshan nuclear power plant was carried out. The results showed that the Activity Median Aerodynamic Diameter( AMAD) for majority of the aerosol particles was below 1μm,while the total aerosol concentration varied with different type of the units.The work provides references for evaluating the effectiveness of the system of sampling for gaseous effluents in the stacks at nuclear power plant.