摘要
根据某大型商业综合体的建筑空间特点及商业流线和使用要求,分析存在的防火设计难点问题,如防火分区面积过大及安全疏散问题,对比分析不同防火设计方案的优缺点,并综合疏散设计给出防火设计策略和解决方案,以保障商业区域的消防安全。设计方案可为类似工程的消防设计提供参考。
According to the commercial requirements and space characteristics of a large commercial complex, the difficulties of fire design were discussed including overlarge fire compartment and problems of safety evacuation, the advantages and disadvan- tages of different fire design plans were compared, and the fire de- sign countermeasure was proposed combined with evacuation de sign, in order to guarantee the fire safety of the building, which could give references for fire safety design of similar projects.
出处
《消防科学与技术》
CAS
北大核心
2017年第7期953-955,共3页
Fire Science and Technology
关键词
建筑防火设计
商业综合体
防火分隔
疏散设计
building fire protection design
commercial complex
fire compartment