综合管廊环境本质安全原则危敏管道敷设技术
Laying Technology of Risk Sensitive Pipeline within Utility Tunnel Based on Inherent Safety Principle
摘要
针对危敏管道敷设在城市地下综合管廊内所引发的安全性问题,从管道服役环境、失效模式、本质安全充分度方面进行探讨。提出管廊本构设计要求、危敏管道(燃气)系统设计要求。
Aiming at the safety problems caused by the laying of risk sensitive pipelines in the urban underground utility tunnel, the pipeline service environ- ment, failure mode and inherent safety adequacy are discussed. The constitutive design requirements of the utility tunnel and design requirements of risk sensitive gas pipeline system are proposed.
出处
《煤气与热力》
2017年第7期11-14,共4页
Gas & Heat
二级参考文献19
-
1陈光(yu),张世箕.数据域测试及仪器-数字系统的故障诊断及可测性设计[M].西安:电子科技大学出版社,2001.
-
2[美]Lala P K.容错与故障可测性系统设计[M].孟永炎,申晓留,等译.北京:中国铁道出版社,1989.
-
3Bennetts R G.Design of testable logic circuits[M].Addision-Wesiey Publishers,Limited,1984.
-
4Fujiwara H.Logic testing and design for testability[M].The Massachusetts Institute of Technology Press,1985.
-
5Reddy S M.Easily testable realizations for logic functions[J].IEEE Trans.on Computers,1972,21:1183-1188.
-
6Treuer R,Fujiwara H,Agarwal V K.Implementing a built-in self-test PLA[J].IEEE Design and Test of Computers,1985,2:37 -48.
-
7Hayes J P.On modifying logic networks to improve their diagnosability[J].IEEE Trans.on Computer,1974,23 (1):56-63.
-
8Saluja K K,Reddy S M.On minimally testable logic network[J].IEEE Trans.on Computer,1974,23 (11):552-554.
-
9Das Gupta S,Hartmann C R P,Rudolph L D.Dual-mode logic for function independent fault testing[J].IEEE Trans.on Computer,1980,29 (11):1025-1029.
-
10Stephenson J E,Grason J.A testability measure for register transfer level digital circuits[A].Proc.6th Int.Symp.,Fault-Tolerant[C].1976:1011-1019.