摘要 强化一级处理工艺成为研究的热点,但是对该工艺中气动絮凝部分研究不足,其控制参数差别很大。通过对气动絮凝的投药量进行试验,分析得出:在试验水质的条件下,PFAC的最佳投加量为150 mg/L,PAM的最佳投加量为0.5 mg/L。 Intensified primary treatment technology has become a hot spot of research, but the research on pneumatic flocculation in this process is not enough. In this paper, the dosage of flocculant dosage during pneumatic flocculation was optimized. The results show that, the optimal dosage of PFAC was 150 mg/L, and the optimal dosage of PAM was 0.5 mg/L.
作者 黄骁 席风祥 贾澍 艾勇 HUANG xiao XI Feng-Xiang JIA Shu AI Yong(Fushun Municipal Environmental Protection Bureau, Liaoning Fushun 113006, China College of Environment and Municipal Engineering,Shenyang Jianzhu University, Liaoning Shenyang 110168, China Liaoning Province Sewage Treatment Control Center, Liaoning Shenyang 110000, China Jinzhou Water Group, Liaoning Jinzhou 121000, China)
出处 《辽宁化工》 CAS 2017年第6期547-549,共3页 Liaoning Chemical Industry
关键词 气动絮凝 絮凝剂 投药量 pneumatic flocculation flocculant dosage