期刊文献+

基于3D打印技术的种植手机引导导板的临床应用 被引量:7

Clinical Application of Handpiece Surgical Guide Based on 3D Printing Technology
下载PDF
导出
摘要 目的:利用CBCT、3D打印技术等设计制作新型口腔种植导板和种植手机引导装置,应用于临床并对其进行精度评价。方法:利用Mimics、Simplant等软件设计制造种植外科导板,分为套筒引导(A组)和种植手机引导(B组)行种植手术。分析虚拟与实际植体的偏差,比较2组的精确度是否有统计学差异。结果:15例患者的92枚植体,A组44枚和B组48枚,测量虚拟与实际植体在颈部、顶部、深度、角度偏离值:(0.82±0.47)mm,(0.97±0.52)mm,(0.81±0.42)mm,(7.89±4.24)°。两独立样本t检验,双侧α=0.05,得到A组和B组差异无统计学意义,不认为两者的偏离值的总体均数不相等。结论:套筒引导和种植手机引导精确度基本无差别,两者的联合应用具有较高的精确性等优点。 Objective:To design a handpiece surgical guide and to evaluate its clinical effect and accuracy using CBCT technology and 3Dprinting.Methods:We designed and manufactured handpiece surgical guide with Mimics,Simplant and other softwares.The patients were carried surgery and divided into sleeve guide group(group A)and handpiece guide group(group B).we analyzed the deviation(entry,apical,vertical,and axis)between virtual and actual implants on preoperative and postoperative CBCT data.Results:Ninety-two implants were inserted into 15 patients,including 44 implants for group A and 48 implants for group B.The deviations of entry,apical,vertical,and axis were(0.82± 0.47)mm,(0.97± 0.47)mm,(0.81± 0.43)mm,and(7.89± 4.26)°,respectively.According to the analysis of variance,the statistical test found no significant difference in apical,vertical and axis between the two groups.Conclusion:There is no significant difference in accuracy between sleeve guide and handpiece guide.A combination of sleeve guide and handpiece guide is advocated.
作者 周勇 陈婉璐 黄文秀 吴东 肖妍君 林东 郭建斌 蒋剑晖 何炳蔚 陈江 ZHOU Vong CHEN Wan -lu HUANG Wen -xiu WU Dong XIAO Yan -jun LIN Dong GUO Jian-bin JIANG Jian-hui HE Bing-wei CHEN Jiang(Department of Oral Implantology , Affiliated Stomatological Hospital of Fujian Medical University, Fuzhou 350002, China Fuzhou University, Fuzhou 350002, China.)
出处 《口腔医学研究》 CAS 北大核心 2017年第7期766-769,共4页 Journal of Oral Science Research
基金 国家卫计委共建科研基金--第四轮福建省卫生教育联合攻关项目(编号:WKJ2016-2-01)
关键词 种植 计算机辅助设计/制作 种植手机引导 3D打印 精度评价 Dental implant Computer aided design and manufacture Handpiece surgical guide 3Dprinting Accuracy evaluation
  • 相关文献

参考文献1

二级参考文献10

  • 1Hammerle, CH, Stone P, Jung, RE, et ah Consensus state- ment and recommended clinical procedures regarding comput-er- assisted implant dentistry [J]. The International Journal of Oral & Maxillofacial Implants, 2009, 24(Suppl. ) : 126- 130.
  • 2Katsoulis J, Pazera P. & Mericske-Stern R. Prosthetically driven, computer-guided implant planning for the edentu- lous maxilla: a model study [J]. Clinical Implant Dentistry and Related Research, 2009, 11 : 238-245.
  • 3Nickenig HJ. & Eitner S. An alternative method to match planned and achieved positions of implants, after virtual plan- ning using conebeam CT data and surgical guide templates-a method reducing patient radiation exposure (part I) [J]. Journal of Craniomaxillofacial Surgery, 2010, 38: 436 -440.
  • 4Sarment DP, Sukovic P, Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide [J]. Int J Oral Maxillofac Implants, 2003, 18: 571-7.
  • 5Cassetta M, Stefanelli LV, Giansanti M, et al. Accuracy of implant placement with a stereolithographic surgical template [J]. IntJ Oral Maxillofac Implants, 2012, 27 : 655-63.
  • 6Valente F, Schiroli G, Sbrenna A. Accuracy of computer- aided oral implant surgery: a clinical and radiographic study [J]. Int J Oral Maxillofac Implants, 2009, 24:234-42.
  • 7Schneider D, Marquardt P, Zwahlen P. & Jung RE. A sys- tematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry [J]. Journal of Clinical Oral Implants Research, 2009, 20(4) : 73 -86.
  • 8Vasak C, Watzak G, Gahleitner, A, et al. Computed tomo- graphy- basedevaluation of template ( Nobel - GuideTM) - guided implant positions: a prospective radiological study [J]. Clinical Oral Implants Research, 2011, 22 : 1157- 1163.
  • 9Sarment DP, Sukovic P, Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide [J]. Int J Oral Maxillofac Implants, 2003, 18: 571-7.
  • 10Arisan V, Karabuda ZC, Ozdemir T. Accuracy of two stere- olithographic guide systems for computer- aided implant placement: a computed tomography-based clinical compara- tive study [J]. J Periodontol, 2010, 81 : 43-51.