空调的使用随着人民生活水平的提高日益增多。所以,寻找一种既节能又环保的空调系统是当务之急。毛细管平面辐射空调系统便在这种大环境下应运而生,其拥有节能、舒适、空气品质良好等诸多优点。通过一个办公建筑模型,对其间歇运行策略进行了分析。根据负荷平衡关系式估算了夏季工况下的预冷时间,推导出预冷时间与室内参数之间的关系式,并举例计算了办公建筑的预冷时间。
Air-conditioning systems find wide application with people's living standard improving. So it is particularly important to find an energy-saving and environmentally friendly air-conditioning system. Capillary plane radiation air conditioning system comes into being in this condition, which has so many advantages, such as energy-saving, comfort, good air quality and so on.This paper sets up an office building model to analyze intermittent operation strategy. Estimates pre-cooling time according to load balance relationship, derives relation between the pre-cooling time and indoor parameters, and calculates the pre-cooling time of an office building by solving of an example.