期刊文献+

热电厂海水冷却塔耐久性修复设计

Design of durability restoration for seawater cooling tower in thermal power station
下载PDF
导出
摘要 某热电厂海水冷却塔在运行6年后,保护涂层失效剥落,混凝土内钢筋遭受腐蚀。根据不同的破损情况,提出相应的修补措施。对环氧类涂层、环氧玻璃鳞片类涂层和纳米无溶剂重防腐涂层在海水冷却塔上的适用性进行验证,并针对不同区域提出相应的涂层配套方案。 After six years of operation, the protective coatings of a seawater cooling tower in a thermal power plant failed due to exfoliation and the steel reinforcements in concretes suffered from corrosion. The methods for repairing the concretes with different damage types were proposed. The applicability of epoxy coating, glass flake/epoxy coating and solvent-free nanometer heavy-duty anticorrosion coating for using in seawater cooling tower was verified by tests. The suitable coating systems for different zones of seawater cooling tower were recommended.
出处 《电镀与涂饰》 CAS CSCD 北大核心 2017年第14期768-772,共5页 Electroplating & Finishing
关键词 海水冷却塔 耐久性 修复 涂层 环氧 重防腐 seawater cooling tower durability restoration coating epoxy heavy-duty anticorrosion
  • 相关文献

参考文献4

二级参考文献16

  • 1张宝胜,干伟忠,陈涛.杭州湾跨海大桥混凝土结构耐久性解决方案[J].土木工程学报,2006,39(6):72-77. 被引量:50
  • 2编委会.混凝土结构耐久性工程设计与施工指南[K].北京:中国建筑工业出版社,2004.
  • 3GB/T50476.2008,混凝土结构耐久性设计规范[S].
  • 4GB/50046-2008,工业建筑防腐蚀设计规范[S].
  • 5JTJ275-2000.海港工程混凝土结构防腐蚀技术规范[S].[S].,..
  • 6同刚,姚友成,王普育,等.海水冷却塔结构防腐蚀研究[J].电力勘探设计,2009(6):40-45.
  • 7杜攀羽.混凝土防腐涂料的抗氯离子侵蚀性能研究[D].杭州:浙江大学,2007.
  • 8余曼丽,蹇守卫,穆松.冻融循环及海水浸泡双重因素对混凝土耐久性的影响[J].中国水运,2007,5(9):58-59.
  • 9Wei Sun, Ru Mu, Xin Luo, et al. Effect of chloride salt, freeze-thaw cycling and externally applied load on the perfor- mance of the concrete[J]. Cement and concrete Research, 2002,32(12): 1859-1864.
  • 10W. Sun, Y. M. Zhang, H. D. Yan, et al. Damage and damage resistance of high strength concrete under the action of foad and freeze-thaw cycles[J]. Cement and concrete Research, 1999, 29 (9): 1519-1523.

共引文献29