期刊文献+

基于波速修正和距离权值的风机叶片损伤定位成像方法

Damage Localization and Imaging Method Based on the Corrected Wave Velocity and the Distance Weighting for Wind Turbine Blade
下载PDF
导出
摘要 针对Lamb波被动监测方法中存在的损伤定位误差较大,检测结果不够直观、准确等问题,以风机叶片为对象,研究了复合材料结构冲击响应波速修正值标定方法和基于像素点对比度的损伤定位成像矩阵,在此基础上提出了基于波速修正值和距离权值的风机叶片损伤定位成像方法。试验结果表明:与传统的被动定位监测相比,该方法损伤定位误差小,成像位置准确。 Aiming at the problem that the damage localization error exists in the Lamb wave passive monitoring method,and the detection result is not intuitive and accurate,a solution for damage localization and imaging for wind turbine blade is proposed that is based on the corrected wave velocity and the distance weighting.The proposed solution assesses the structure of wind turbine blade and studies the revised velocity of shocking response wave demarcating method to the structure of composite material and damage location based on pixel contrast imaging matrix.The provided experiment results demonstrate that compared with traditional passive positioning monitoring,the locating error of the proposed method is smaller and the imaging position is more accurate.
出处 《无损检测》 2017年第7期33-37,57,共6页 Nondestructive Testing
基金 国家自然科学基金重点资助项目(61533010) 中国博士后基金资助项目(2015M570401) 南京邮电大学先进技术研究院开放基金资助项目(XJKY15005) 南京邮电大学科研资助项目(NY215093)
关键词 LAMB波 被动监测方法 风机叶片 定位成像矩阵 波速修正值 距离权值 Lamb wave passive monitoring method wind turbine blade orientation imaging matrix corrected wave velocity distance weighting
  • 相关文献

参考文献5

二级参考文献45

  • 1杨瑞峰,马铁华.声发射技术研究及应用进展[J].中北大学学报(自然科学版),2006,27(5):456-461. 被引量:77
  • 2刘晓波,王依,林家国.基于有限元法的风机叶片裂纹分析及处理[J].机械设计与制造,2007(3):98-100. 被引量:4
  • 3张春丽,黄争鸣,董国华.基于非线性本构关系的复合材料风机叶片有限元极限分析与设计[J].复合材料学报,2007,24(2):174-183. 被引量:18
  • 4Lekou D, Vionis P, Joosse P A, et al. Full-scale blade testing enhanced by acoustic emission monitoring[C]. Proc European Wind Energy Conference, Madrid, Spain, 2003.
  • 5Paquette J, Van Dam J, Hughes S. Structural testing of 9m carbon fiber wind turbine research blades[C]. AIAA 2007 Wind Energy Symposium, Reno, USA,2007.
  • 6Dam J van, Eric Jacobson, Hal Link, et al. Wind turbine generator system duration test report for the altantic orient 15/50 wind turbine[R]. National Wind Technology Center, 2003.
  • 7Sφrensen B F. Improved design of large wind turbine blade of fibre composites based on studies of scale effects (Phase 1) Summary Report[R]. Riso National Laboratory, Denmark, 2004.
  • 8Musial W, Butterfield S, McNiff B. Improving wind turbine gearbox reliability[C]. European Wind Energy Conference, Milan, Italy, 2007.
  • 9Polak S. Gearbox & Gear System problems[EB/OL]. http://www. tribology. co. uk/publish/p004. htm.
  • 10Tavner P J. Review of condition monitoring of rotating electrical machines[J]. IET Electric Power Applications,2008,2(4):215-247.