摘要
以华为Metro1000传输设备因电源板故障和时钟板故障造成同步源劣化的两个故障为例,分析处理时钟劣化故障的方法与思路,加强日常维护与信息分析,提高解决故障的速度和准度。
HUAWEI Metro1000 transmission equipment for power supply and Clock failure cause synchronous source degraed as an example,Analysis and treatment of clock degradation failure,strengthen the daily maintenance and troubleshooting information, improve the speed and accuracy.
出处
《广西通信技术》
2017年第1期54-56,共3页
Guangxi Communication Technology