摘要
本文介绍了人防地下室固定电站的降温冷却设计方法。根据工程实例对柴油发电机房内余热的构成,送排风机及冷风机的设备选型、冷却水池及混合水池的选型进行了详细的分析和计算,并给出了冷却水系统原理图、柴油发电机房通风原理图和平时运行与战时运行的通风方式操作顺序表。
The cooling design of fixed power station in civil air defense basement was introduced. Based on the project example, the composition of the waste heat in the diesel generator room, the model selection of blowing, exhausting and cooling fans, and the selection of cooling and mixing pool were analyzed and computed in detail. The schematic diagram of the water cooling system, the ventilation system in the diesel generator room, and the sequence table of ventilation operation in both peacetime and wartime were drawn.
作者
吴兆武
WU Zhao-wu(CITIC General Institute of Architectural Design and Research Co., Ltd)
出处
《建筑热能通风空调》
2017年第7期102-105,共4页
Building Energy & Environment
关键词
固定电站
降温冷却
余热
送排风
冷风机
冷却水池
混合水池
fixed power station, cooling, waste heat, blowing and exhausting, cooling fan, cooling pool, mixing pool