注入式低压智能开关技术研究 被引量:1

Research on Injection Low Voltage Intelligent Switch Technology
下载PDF
导出
摘要 研制了一种在合闸前对线路故障进行检测的注入式低压智能开关。开关在出现故障分闸时,通过短信将故障以及定位信息发送到检修人员手机上;再通过向系统中注入小电压,对用户侧的电气量进行采集,并判断检测系统中的故障是否存在以及故障类型。试验验证能对系统中出现的故障进行检测,避免带故障重合闸的危险,通过GPRS通信将故障点的位置第一时间发送到检修人员手机App,并通过App自动定位故障开关位置并进行路径规划,最快时间到达现场,减少停电时间。 This paper developed an injection low voltage intelligent switch which can detect the line fault before closing. In the event of fault tripping, it sends the fault and location information to the maintenance personnel phone throngh SMS, and them by injecting a swall voltage to the system, collects the electrical quantity of user side and judges the presence of faults in the system and detects the type of failure,The tests show that it can detect the fault in the sysrem to avoid the risk of reclosing with the fault, and send the fault position to the maintenance personnel phone throngh GPRS the first time, through the App antomatically locate the fault switch location and path planning, to reach the scene the fastest time, reducing the power outage time.
作者 陈琛 周强 欧传刚 CHEN Chen ZHOU Qiang OU Chuangang(NARI Technology Development Co. , Ltd. , Nanjing 211106, China)
出处 《电器与能效管理技术》 2017年第14期38-41,共4页 Electrical & Energy Management Technology
关键词 低压智能开关 注入式 GPRS通信 GPS定位 故障检测 low voltage intelligent switch injection GPRS communication GPS positioning fault detection
  • 相关文献

参考文献3

二级参考文献30

  • 1张永文,钟晓明.低压配电系统的选择性保护技术[J].电气技术,2007,8(9):59-64. 被引量:8
  • 2林湘宁,刘海峰,鲁文军,刘沛,薄志谦.基于广义多分辨形态学梯度的自适应单相重合闸方案[J].中国电机工程学报,2006,26(7):101-106. 被引量:35
  • 3宋国兵,索南加乐,孙丹丹.输电线路永久性故障判别方法综述[J].电网技术,2006,30(18):75-80. 被引量:67
  • 4王成多,张秋璇,朱建波,杨利峰.区域联锁选择性保护装置[J].低压电器,2007(13):39-42. 被引量:2
  • 5S&C electric company. S&C IntelliRupter PulseCloser [EB/OL]. (2010-03-22)[2011-08-26]. http://www.sandc. com/edocs_pdfs/EDOC_ 036231 .pdf.
  • 6David A R, Lloyd R B, Gerald B R, et al. Fault detection system including a capacitor for generating a pulse and a processor for determining admittance versus frequency of a reflected pulse: United States, 5650728[P]. 1997-07-22.
  • 7Xu W, Zhang G B, Li C, et al. Apower line signaling based technique for anti-islanding protection of distributed generators-Part h Scheme and analysis[J]. IEEE Trans. on Power Delivery, 2007, 22(3): 1758-1766.
  • 8Wang W C, Zhu K, Zhang P, et al. Identification of the faulted distribution line using thyristor-controlled grounding[J]. IEEE Trans. on Power Delivery, 2009, 24(1): 52-60.
  • 9Zhu K, Zhang P, Wang W C, et al. Controlled closing of PT delta winding for identifying faulted lines[J]. IEEE Trans. on Power Delivery, 2011, 26(1):79-86.
  • 10Fisher L E. Resistance of low-voltage AC arcs[J]. IEEE Trans. on Industry and General Applications, 1970, 6(6): 607-616.

共引文献9

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部