摘要
济钢燃气厂针对济钢转炉煤气储存加压系统的设备现状,组织了一次设备大修,大修后煤气柜升降速度提高到了1.0m/min,并解决了加压机前负压等问题。
In the light of the current state of the storage and pressuring system of converter gas of Jinan Iron &Steel Group Co., a major overhaul of the equipment was carried out. After the major overhaul lift speed of the gas holder was raised to 1.0 m/min and some problems were solved, for example fore negative pressure of the pressure machine.
出处
《冶金动力》
2002年第4期35-37,共3页
Metallurgical Power
关键词
转炉
煤气
储存加压系统
缺陷
处理措施
济南钢铁厂
converter gas
wet spiral gas holder
deformation
negative pressure
dust on impeller