介绍了高温冷水的双冷源热泵全热回收新风空调工作原理及适合温湿度独立控制系统的应用,测试了机组出风状态所能达到的含湿量及能效比,通过排风能量全热回收及热泵冷凝热回收技术与系统16℃~19℃高温冷水的综合应用,计算了机组的节能潜力。
Introduces the double cold heat cold water source heat pump heat recovery air conditioning work principle and suitable for the application of temperature and humidity independent control system,tested the unit state can achieve the wind out of moisture content and can effect comparing,through the full heat recovery and exhaust air energy heat pump condensing heat recovery technology with 16 ℃ - 19 ℃ high temperature cooling water system of integrated application,calculation of the unit energy-saving potential.