摘要
本文通过对M8612A花键磨床工作台运动与头架分度联锁失灵故障的分析、排除,揭示了液压传动系统微量渗漏对液压系统工作稳定性的直接影响。
This article based on M 8612A spline - grinder worktable movement and the head - post indexing - interlock mal- function breakdown ’ s analysis and troubleshooting. Reveals the micro leaks of hydraulic system directly affect the stability of the work.
出处
《江西化工》
2017年第4期114-116,共3页
Jiangxi Chemical Industry
关键词
花键磨床
液压联锁
渗漏
液压故障排除
Spline - grinder hydraulic system interlock leakage hydraulic system troubleshooting