摘要
分析了综合管廊设防水位的确定方法。结合管廊结构特点,考虑了管廊侧壁摩阻力,研究在不同地下水位下管廊所受水浮力与计算方法,并进行工程抗浮算例验证,研究结果可为抗浮设计提供参考。
The method ascertaining the water level for prevention of up-floating was analyzed. Combining the structure characteristic of utility tunnel and considering the side friction of utility tunnel, the buoyancy of water and computation method were studied, and the example of engineering anti-floating was checked. The research results can provide references for anti-floating design of utility tunnel.
出处
《混凝土与水泥制品》
2017年第8期37-40,共4页
China Concrete and Cement Products
基金
国家自然科学基金资助项目(51474050)
地质灾害防治与地质环境保护国家重点实验室项目(SKLGP2014K011)
关键词
综合管廊
水浮力
设防水位
侧壁摩阻力
Utility tunnel
Buoyancy of water
Water level, for prevention of up-floating
Side friction