期刊文献+

熟食品真空冷却机的改进设计 被引量:1

Improved Design of Vacuum Cooling Machine for Cooked Food
下载PDF
导出
摘要 为了解决熟食品真空预冷过程中,封闭式捕水器不易清洗,自来水补水不均匀,空气回压导致二次污染等问题,设计了一种集冷却、补水、杀菌、回压一体化的全自动新型真空预冷机。采用罗茨-水环真空机组解决了封闭式捕水器的弊端;采用小分子水替代自来水,改善补水的不均匀问题;采用臭氧发生器设计臭氧回压模块,解决了空气污染问题。根据初始性能参数,对设备进行了理论计算和选型。改进设计的的新型真空预冷机易于清洗、补水均匀,有效解决了常规真空预冷机在工业应用中存在的问题,具有实际应用价值。 In order to solve the problem of vacuum pre-cooling of cooked food that closed-type water trap is not easy to clean, the tap water replenishment is not uniform, the air back pressure causes secondary pollution and so on, a new set of cooling, replenishment, sterilization, back pressure integration automatic vacuum pre-cooling machine was designed. Roots-water ring vacuum pump unit was used to solve the shortcomings of closed-type water trap; Small molecules of water was used to improve the replenishment of non-uniform problems; ozone generator was adopted to design an ozone back pressure module to solve the air pollution problems. According to the initial performance parameters, the equipment was calculated and selected. This improved design solved the problems of conventional vacuum pre-cooling machine in industrial application effectively, and had practical application value.
作者 刘山山 李保国 顾小杰 LIU Shanshan LI Baoguo GU Xiaojie(School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 20093, China Shanghai Izzlang Machinery Equipment Co. , Ltd. ,Shanghai 201201 ,China)
出处 《轻工机械》 CAS 2017年第4期65-68,共4页 Light Industry Machinery
关键词 真空预冷机 臭氧杀菌 小分子水 开式捕水器 vacuum precooling machine ozone sterilization small molecules of water open collector
  • 相关文献

参考文献6

二级参考文献49

  • 1程世利.现代温室环境控制[J].农业装备技术,2004,30(6):7-9. 被引量:8
  • 2谢晶,华泽钊.速冻马铃薯在高压直流电场中解冻的实验研究[J].制冷学报,2001,22(2):1-5. 被引量:4
  • 3关志强,蒋小强.食品热焓和比热容的经验计算公式[J].食品工业,2006,27(3):55-58. 被引量:8
  • 4-.食品生物化学[M].北京:轻工业出版社,1989..
  • 5毕龙生 陈光奇.多层绝热低温容器真空夹层中的残余气体质谱分析.真空科学与技术,1987,7(5):325-330.
  • 6J.K. Fremerey. Residual gas: traditional understanding and new experimental results [ J]. Vacuum, 1999,53 (1 -2) :197 -201.
  • 7Hong S S, Shin Y H, Kim J T. Residual gas survey of stainless steel 504 extreme high vacuum chamber with hot cathode ionization gauge [ J ]. Measurement, 2008, 41 (9) :1026 - 1031.
  • 8Bennett J R J, Hughes S, Elsey R J, et al. Outgassing from stainless steel and the effects of the gauges [ J ]. Vacuum, 2004,73 (2) : 149 - 153.
  • 9Nemanic V, Zumer M, Zajec B. The influence of a hot cathode vacuum gauge on the residual gas composition [J]. Vacuum, 2003,70(4):523 -530.
  • 10Abdel- Samad S, Abdel- Bary M, Kilian K. Residual gas analysis in the TOF vacuum system [ J ]. Vacuum, 2005,78 ( 1 ) :83 - 89.