摘要 为提高供热管网运行监测水平,特别是水力模型校核精度,提出了一种利用管网运行条件下观测数据的阻抗辨识方法——基于广义逆矩阵理论辨识供热管网阻抗。利用线性化迭代方法求解辨识方程组的广义逆解,并以该解中的阻抗值作为辨识结果。介绍了该辨识方法在一个算例供热管网的应用,分析了观测数据误差和观测点数量对阻抗辨识结果的影响。与已有阻抗辨识方法相比,该方法具有较高的辨识准确度和计算效率。 To increase monitoring level of heat supply networks, especially accuracy of hydraulic models, proposes an impedance identification method based on generalized inverse matrix theory using observation data under realistic operation conditions. Solves the generalized inverse solution of the identification equations by a linearization iteration methodology, and confirms the impedance values in the generalized inverse solution as the identification results. Presents the application of the identification method to a heat supply network case. Analyses the influences of the observation data error and the number of observation points on the identification results. This method has higher accuracy and calculation efficiency compared with existing impedance identification method.
作者 刘永鑫 金虹 邹平华 Liu Yongxin Jin Hong Zou Pinghua(Harbin Institute of Technology, Harbin, Chin)
机构地区 哈尔滨工业大学
出处 《暖通空调》 北大核心 2017年第8期116-121,共6页 Heating Ventilating & Air Conditioning
基金 黑龙江省博士后经费资助项目(编号:LBH-Z15083) 中央高校基本科研业务费专项基金资助项目(编号:HIT.NSRIF.2015073)
关键词 供热管网 阻抗辨识 迭代求解 广义逆矩阵 观测数据 观测点 heat supply network, impedance identification, iterative solution, generalized inversematrix, observation data, observation point
  • 相关文献

参考文献3

二级参考文献20

  • 1韩德宏.配水管网状态估计的几种方法[J].中国给水排水,1993,9(1):31-33. 被引量:6
  • 2周金萍 王冉 吴斌.MATLAB6实践与提高[M].北京,中国电力出版社,2001..
  • 3Rahal H. A Co-tree flows formtflation for steady state in water distribution networks. Advance Software,1995,22(3) :169 -178.
  • 4Kapelan Z S, Savic D A, Waiters G AI Optimal sampling de- sign methodologies for water distribution model calibration. Journal of Hydraulic Engineering, 2005, 131 (3) : 190 - 200.
  • 5Leaksin Pudar R S, Liggett J pipe networks. Journal of Hydraulic Engineering, 1992, 118(7): 1031- 1046.
  • 6Nixon W, Ghidaoui M S, Kolyshkin A A. Range of validity of the transient damping leakage detection method. Journal of Hydraulic Engineering, 2006, 132 (9) : 944 - 957.
  • 7Liggett J A, Chen L C. Inverse transient analysis in pipe network. Journal of Hydraulic Engineering, 1994, 120 (8) : 934 - 955.
  • 8Kapelan Z S, Walters G A, Savic D A. A hybrid inverse transient model for leakage detection and roughness calibra- tion in pipe networks. Journal of Hydraulic Engineering, 2003, 41(5) : 481 -492.
  • 9Qin x z, Jiang Y. Identification of flow resistance coeffi- cient and fault diagnosis in district heating networks. Jour- nal of Tsinghua University (Science and Technology ), 2000, 40(2) : 81 -85.
  • 10Zhou Z G. Study on Identification Resistance Coefficient of Heat-supply Networks. Harbin: Harbin Institute of Tech- nology, 2006.