摘要
单相接地故障是中压船舶电力系统中的频发故障,容易发展成严重的短路故障而威胁系统运行安全。为充分了解该类故障,结合实际中压船电系统给出了零序等效网络,分析了系统中出现单相接地故障时零序电流的分布情况,并以表达式和矢量图的形式阐明了故障线路与非故障线路上零序电流的幅值与相位特征。在MATLAB中建立动态仿真模型验证了分析和结论,为单相接地故障的继电保护提供了参考。
The single-phase-grounding fault is a frequent failure in marine middle voltage power grid, it is easy to develop into serious short-circuit fault which threatens on the system operation safety. In order to understand such failure in detail, zero-sequence equivalent network is provided according to the practical MV ship grid, the distribution of zero-sequence current with single-phase-grounding fault in system is analyzed, and the zero-sequence current characteristic of magnitude and phase of fault and non-fault lines are liberated in the form of expressions and vector diagram. Finally, the provided analysis and conclusions are verified by dynamic simulation s established in MATLAB, which could provide reference of relay protection of single-phase-grounding fault.
出处
《船电技术》
2017年第8期10-14,共5页
Marine Electric & Electronic Engineering
基金
国家发展和改革委员会2015年海洋工程装备专项支持
发改办高技[2015]1409号
关键词
中压船舶电网
单相接地故障
零序电流
继电保护
marine medium voltage power grid
single-phase-grounding fault
zero-sequence current
relay protection