目的评估生物阻抗谱检测技术(BIS)在乳腺肿物切除术中对所切除包块良恶性快速定性的准确度。方法本临床试验选取2015年1月至2016年5月之间成都市第三人民医院(西南交通大学附属医院)收治的189例乳腺肿物切除患者的237个包块进行检测,同一标本按顺序先后使用乳腺组织阻抗分析仪(MScan1.0B)与石蜡切片活组织检查技术进行检测,在该标本的几项检测结果全部得到以后,将MScan1.0B的检测结果与病理切片结果进行统计学分析,以石蜡切片活组织检查的检测结果为金标准,评估MScan1.0B检测的特异度和敏感度,采用McNemar χ~2检验比较2种方法的检出差异。采用Kappa检验进行2种方法的一致性检验。结果 BIS的敏感度为93.75%(45/48),特异度为96.30%(182/189),假阳性率为3.70%(7/189),假阴性率为6.25%(3/48),阳性似然比为25.31,阴性似然比为0.06。2种方法的检出效果差异无统计学意义(P=0.344)。BIS与石蜡切片活组织检查的一致性较高(Kappa=0.87,P<0.001)。结论 BIS对乳腺肿物的良恶性鉴定准确度高,可以弥补术中冰冻活组织检查对于某些乳腺肿物不能做出快速判断的不足,而且实现成本低、高效率、操作简便,在进一步更新后有望成为临床快速组织鉴定的补充技术手段。
Objective To evaluate the accuracy of bioelectrical impedance spectroscopy (BIS) in rapidly distinguishing malignant breast mass from benign mass. Methods We selected the specimens from 237 breast masses in 189 patients from January 2015 to June 2016 in the Third People's Hospital of Chengdu (the Affiliated Hospital of Southwest Jiaotong University) for clinical trials. Each specimen was detected sequentially by Breast Tissue Bioimpedance Analyser ( MScanl. 0B) and pathological examination of paraffin sections. With pathological results as gold standard, the specificity and sensitivity of MScanl. 0B detection were evaluated. McNemar Xz test was used to analyze the difference between MScanl. 0B and pathological examination. Kappa test was used to check the consistency of the two methods. Results The sensitivity of BIS was 93.75% (45/48), the specificity 96. 30% ( 182/189), false positive rate 3.70% (7/189), false negative rate 6. 25% (3/48), positive likelihood ratio 25.31 and negative likelihood ratio 0. 06. There was no significant difference in detection efficacy between the two methods ( P = 0. 344). BIS technique had high consistence with pathologic examination (Kappa = O. 87,P〈0. 001 ). Conclusion BIS can identify the benign and malignant breast masses with advantages of high accuracy, low cost, high efficiency and simple operation, which overcomes the shortcomings of intraoperative frozen section biopsy and has potential as a supplementarymethod of pathological examination for clinical identification.
作者
吴剑
王品
唐艳
罗静
姚欣敏
刘虹
张艳
陈丽萍
许章波
张文杰
Wu Jian Wang Pin Tang Yah Luo Jing Yao Xinminl Liu Hong Zhang Yah Chen Liping Xu Zhangbo Zhang Wenjie(Department of Breast and Thyroid Surgery Department of Pathology, Third People's Hospital of Chengdu/Affiliated Hospital of Southwest Jiaotong University, Chengdu 610031, China)
出处
《中华乳腺病杂志(电子版)》
CAS
CSCD
2017年第4期203-207,共5页
Chinese Journal of Breast Disease(Electronic Edition)
基金
四川省科学技术厅应用基础计划项目(2015JY0190)
关键词
乳腺肿瘤
诊断
检测
手术中
电阻抗
Breast neoplasms
Diagnosis
Monitoring, intraoperative
Electric impedance