摘要
目的:建立一种化学雾化冷原子吸收光谱法测定人尿中汞含量的方法。方法:样品经加酸定容处理后,通过对介质酸度、硼氢化钠浓度、载气流速的优化,直接测定人尿中汞的含量。结果:在选定的条件下,该方法的检出限(3σ)为0.038μg/L,回归方程:y=0.06749x+0.00562,线性范围:0~5.0μg/L,回收率95.2~104.8%,相对标准偏差(RSD,n=7)为1.46~3.23%。结论:本方法准确、可靠、无记忆效应,适合大批量人尿中汞的简便快速测定。
The sample was treated with acid solution. After optimization of the medium acidity, con- centration of sodium borohydride and carrier gas flow rate, it can be determinated. Under the selected con- ditions, the detection limit (σ) was 0. 038μg/L, the regression equation was y=0. 06749x+0. 00562, and the linear range was 0--5.0μg/L, the recoveries of Hg from spiked sample was 95.2%--104.8%, with relative standard deviation (RSD) 1.46%--3.23% (RSD, n=7). This method has no memory effect and is accurate, reliable and suitable for rapid determination of Hg in large quantities of human urine.
作者
曹骁
Cao Xiao(Yuhang District Hangzhou of Supervising& Testing Center for Quality And Measurement, Hangzhou 311100, China)
出处
《分析仪器》
CAS
2017年第4期32-35,共4页
Analytical Instrumentation
关键词
化学雾化法
冷原子吸收法
汞
尿液
chemical atomizer
cold atomic absorption spectrometry
mercury
urine