摘要 参照ISO 2561:2012,采用气相色谱法测定聚苯乙烯中的残余苯乙烯[1],将聚合物样品溶于含有正丁基苯内标物的N,N-二甲基甲酰胺溶剂中,然后将少量聚合物溶液直接注入气相色谱中(方法 A);或将沉淀剂加入到聚合物溶液中,待沉淀后取上层清液注入到气相色谱中进行测定(方法 B)。测定结果的重复性满足方法重复性±5%的要求,两种方法的回收率都在100±5%范围内。 Residual styrene contained in polystyrene was determined in this paper with reference to ISO 2561:2012, using gas chromatography. The polymer samples were dissolved in N, N-dimethylformamide (DMF) solvent and n-butyl benzene was used as internal standard substance. A little polymer solution was directly injected into gas chromatograph(method A) or precipitant was added into polymer solution, and then supernatant after precipitation would be injected into gas chromatograph (method B). The test re- suits of two methods showed that the repeatability errors were ±5% and recovery rates were 100±5%, they all can meet the test requirement.
作者 郑利红 蔡登定 米燕 高玲 谢力潘 Zheng Lihong Cai Dengding Mi Yan Gao Ling Xie Li pan(PetroChina Dushanzi Petrochemical Co. , Dushanzi 833600, Chin)
出处 《分析仪器》 CAS 2017年第4期62-67,共6页 Analytical Instrumentation
关键词 聚苯乙烯 气相色谱法 polystyrene gas chromatograph
  • 相关文献

参考文献1

二级参考文献7

  • 1中国实验室认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社出版,2002.78.
  • 2GB/T16867-1997.聚苯乙烯和丙烯腈一丁二烯一苯乙烯树脂中残留苯乙烯单体的测定:气相色谱法(A法).
  • 3国家质量监督检验检疫总局.JJG700-1999.气相色谱仪检定规程[S].北京:中国计量出版社.
  • 4国家质量监督检验检疫总局.JJFl059-1999.测定不确定度评定与表示[S].北京:中国计量出版社.
  • 5国家质量监督检验检疫总局.JJGl96-2006.常用玻璃量器检定规程[S].北京:中国计量出版社.
  • 6国家质量监督检验检疫总局.JJGl036-2008.电子天平检定规程[S].北京:中国计量出版社.
  • 7袁丽凤,崔家玲,孙君猛,华正江.聚苯乙烯树脂中残留苯乙烯含量不确定度评定[J].中国计量,2008(8):68-70. 被引量:1

共引文献1

同被引文献15

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部