摘要
针对某核电厂主泵电机轴承漏油问题进行原因分析。分析认为,电机运行时产生的"风扇"效应、轴承箱尺寸和储油量限制、未设置有效的润滑油凝结收回装置等是下导轴承润滑油、油气泄漏的主要原因。经计算流体动力学(CFD)分析表明,通过在下导轴承上方设置隔板、密封,在上、下轴承上方增设油气凝结装置及回油通道,可在不改变电机现有主体结构和轴承内部构件的基础上,进一步改善电机轴承漏油问题。
In this paper, cause analysis of reactor coolant pump motor oil leakage is performed, and suggested solutions are presented. Based on the CFD analysis result, supplementary baffle and seal can reduce the fan effect on the lower guide bearing caused by flywheel, and the supplementary condensate device and oil recycling pipe can recover the possible oil and oil mist leakage. The solutions mentioned above can reduce the oil leakage and oil mist leakage of this motor.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2017年第4期104-107,共4页
Nuclear Power Engineering
关键词
主泵
电机
轴承
漏油
改进建议
Reactor coolant pump, Motor, Bearing, Oil leakage, Suggested solution