医用乳腺X射线摄影成像系统AEC性能检测的重要性及检测方法探讨 被引量:1

Discussion on the Detection Methods of Automatic Exposure Control for Medical Breast X Ray Radiography Imaging System
下载PDF
导出
摘要 自动曝光控制(AEC)是现代医用乳腺X射线摄影成像系统的重要性能参数,在保证图像质量和最大限度降低辐射剂量方面起着至关重要的作用。但是国内对医用乳腺X射线摄影成像系统的自动曝光控制(AEC)参数并没有完整、统一的计量参数评价指标,该文主要对此参数的检测重要性和检测方式方法进行研究探讨。
作者 郑小清
出处 《计量与测试技术》 2017年第8期110-112,共3页 Metrology & Measurement Technique
  • 相关文献

参考文献2

二级参考文献34

  • 1KANAGA K C. YAP H H. LAlLA S E. et al. A critical comparison of three full field digital mammography systems using figure of merit[J]. MedJ Malaysia. 2010. 65(2): 119- 122.
  • 2DONG S L. SUJ L. YEH Y H. et al, Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance[J]. BrJ Radiol , 2011. 84(10): 350-357.
  • 3DIMITRIC D. NISEVIC G. BOSKOVIC Z. et al. A study on performance of a digital image acquisition system in mammography diagnostic[C]// XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010. Berlin: 2010: 331-334.
  • 4SALVAGNINIA E. BOSMANSA H. MONNINB P. et al. The use of detectability indices as a means of automatic exposure control for a digital mammography syste[C]// Medical Imaging 2011: Physics of Medical Imaging. Lake Buena Vista: 2011: 79615J.
  • 5EGAN G. KEAVEY E. PHELAN N. Comparison of contact spot imaging on a scanning mammography system to conventional geometric magnification imaging[C]// MAIDMENT A D A. BAKIC P R. GAVENONIS S. Proceedings of the 11th International Conference on Breast Imaging. Berlin: Springer Berlin Heidelberg. 2012: 165-172.
  • 6VARJONEN M. STROMMER P. OY P. Anatomically adaptable automatic exposure control (AEC) for amorphous selenium (a-Se) full field digital mammography (FFDM) system[C]// Medical Imaging 2006: Physics of Medical Imaging. San Diego: 2006: 614207.
  • 7CASTELLANOS I M. KACZMAREK R. BRUNNER C C. et al. Evaluation of automatic exposure control performance in Full-Field digital mammography systems using Contrast-Detail analysis[C]// Medical Imaging 2012: Physics of Medical Imaging. San Diego: 2012: 831341.
  • 8SHRAMCHENKO N. BUN P. MATHEY C. et al. Optimized exposure control in digital mammography[C]// Medical Imaging 2004: Physics of Medical Imaging. San Diego: 2004: 445-456.
  • 9MCCULLAGHJ B. BALDELLI P. PHELAN N. Clinical dose performance of full field digital mammography in a breast screening programme[J]. BrJ Radiol , 2011. 84(17): 1027- 1033.
  • 10WILLIAMS M B. RAGHUNATHAN P. MORE MJ. et al. Optimization of exposure parameters in full field digital mammography[n. Med Phys , 2008. 35(6): 2414-2423.

共引文献2

同被引文献17

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部