期刊文献+

任意阶运动目标强度关联成像 被引量:1

Nth-order intensity correlated imaging for moving target
下载PDF
导出
摘要 开展了强度关联阶数对于运动目标关联成像影响的研究,通过改变信号光束和参考光束的阶数,分别讨论了切向和轴向运动目标在不同强度关联阶数下的关联成像质量。在运动目标关联成像系统原理光路的基础上,从理论上重点分析了不同强度关联阶数对关联成像计算模型的影响,并且利用计算机进行了仿真实验。结果表明:强度关联阶数的改变不能消除运动模糊,增加信号光束的阶数可以改善关联成像质量,但是在去除背景项的情况下,反而是最低阶的关联成像质量最好,并且轴向运动目标的关联成像质量下降地更为严重。 The influence of intensity correlation order on correlated imaging for moving target was researched. The image quality of correlated imaging for tangential and axial moving target in different intensity correlation order was discussed by changing the signal light order and the reference light order. Based on the schematic of Nth-order lensless correlated imaging for moving target, analysis of the influence of different intensity correlation order was performed with emphasis on the correlated imaging mathematic model, and the simulation experiments were performed. The results suggest that it can not effectively eliminate the motion blur by changing the intensity correlation order, and the image quality will be better with the increase of signal light order. However, the best quality can be obtained by the lowest-order with background subtraction, and the image quality of axial moving target will decrease more serious.
出处 《红外与激光工程》 EI CSCD 北大核心 2017年第8期232-239,共8页 Infrared and Laser Engineering
基金 国家自然科学基金(61307025) 安徽省自然科学基金(1308085MF114)
关键词 关联成像 强度关联阶数 运动目标 成像质量 correlated imaging intensity correlation order moving target image quality
  • 相关文献

参考文献6

二级参考文献97

  • 1黄有为,金伟其,王霞,曹峰梅,王岭雪.凝视型水下激光成像后向散射光理论模型研究[J].光学学报,2007,27(7):1191-1197. 被引量:18
  • 2P. H. S. Ribeiro, S. Pddua, J. C. M. da Silva et al.Controlling the degree of visibility of Youngrs fringes with photon coincidence measurements [J]. Phys. Rev. A, 1994, 49 (5) 4176-4179.
  • 3D. Strekalov, A. Sergienko, D. Klyshko et al. Observation of two-photon "ghost" interference and diffraction[J]. Phys. Rev. Lett. , 1995, 74(18): 3600-3603.
  • 4R. S. Bennink, S. J. Bentley, R. W. Boyd. " Two-photon" coincidence imaging with a classical source[J]. Phys. Rev. Lett. , 2002, 89(11): 113601.
  • 5J. Cheng, S. Ham Incoherent coincidence imaging and its applicability in X-ray diffraetion[J]. Phys. Rev. Lett., 2004, 92(9) . 093903.
  • 6A. Gatti, E. Brambilla, M. Bache et al. Ghost imaging with thermal light: comparing entanglement and classical correlation [J]. Phys. Rev. Lett. , 2004, 93(9): 093602.
  • 7J. Xiong, D. Z. Cao, F. Huang et al. Experimental observation of classical subwavelength interference with a pseudothermal light source. Phys. Rev. Lett. , 2005, 94(17) : 173601.
  • 8D. Zhang, Y. H. Zhai, L. A. Wuetal. Correlated two-photon imaging with true thermal light[J]. Opt. Lett. , 2005, 30(18): 2354-2356.
  • 9A. Valencia, G. Scarcelli, M. D. Angelo et al. Two-photon imaging with thermal light[J]. Phys. Rev. Lett., 2005, 94(6): 0636O1.
  • 10D. Z. Cao, J. Xiong, K. Wang. Geometrical optics in correlated imaging svstems[JT. Phys. Rev. A, 2005, 71(1). 013801.

共引文献52

同被引文献10

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部