摘要
本文在结合机组微增功率、背压关系曲线、凝汽器变工况等内容创建了冷端优化数学模型,并提出了采用与循环水泵运行优化调整试验相结合的方式,制定机组在不同运行负荷、冷却水进口温度下冷端循环水泵的最佳运行方式。
Unit in this paper, in combination with micro power, back pressure curve, the condenser load created the cold end optimization mathematical model, and puts forward some operation optimization adjustment of water circulating pump is used to test the way of combining formulation unit in the cold end under different operation load, cooling water inlet temperature of circulating water pump optimal operation mode.
出处
《电子测试》
2017年第8期88-89,共2页
Electronic Test
关键词
汽轮机
冷端优化
steam turbines
The cold end optimization