摘要 A series of experiments was carried out to study the flow behaviour behind a rotationally oscillating cylinder at a low Reynolds number (Re=300) placed in a recirculation water channel. A stepper motor was used to rotate the cylinder clockwise- and- counterclockwise about its longitudinal axis at selected frequencies. The particle image velocimetry (PIV) technique was used to capture the flow field behind a rotationally oscillating cylinder. Instantaneous and time-averaged flow fields such as the vorticity contours, streamline topologies and velocity distributions were analyzed. The effects of four rotation angle and frequency ratios Fr (Fr=fn/fv, the ratio of the forcing frequency fn to the natural vortex shedding frequency fv) on the wake in the lee of a rotationally oscillating cylinder were also examined. The significant wake modification was observed when the cylinder undergoes clockwise-and-counterclockwise motion with amplitude of π, especially in the range of 0.6≤Fr≤1.0. A series of experiments was carried out to study the flow behaviour behind a rotationally oscillating cylinder at a low Reynolds number (Re=300) placed in a recirculation water channel. A stepper motor was used to rotate the cylinder clockwise- and- counterclockwise about its longitudinal axis at selected frequencies. The particle image velocimetry (PIV) technique was used to capture the flow field behind a rotationally oscillating cylinder. Instantaneous and time-averaged flow fields such as the vorticity contours, streamline topologies and velocity distributions were analyzed. The effects of four rotation angle and frequency ratios Fr (Fr=fn/fv, the ratio of the forcing frequency fn to the natural vortex shedding frequency fv) on the wake in the lee of a rotationally oscillating cylinder were also examined. The significant wake modification was observed when the cylinder undergoes clockwise-and-counterclockwise motion with amplitude of π, especially in the range of 0.6≤Fr≤1.0.
出处 《China Ocean Engineering》 SCIE EI CSCD 2017年第4期495-503,共9页 中国海洋工程(英文版)
基金 financially supported by the National Natural Science Foundation of China(Grant Nos.51409231,51479175,and51679212) Zhejiang Provincial Natural Science Foundation of China(Grant Nos.LY14E090009 and LR16E090002) the Scientific Research Foundation for the Returned Overseas Chinese Scholars,the Ministry of Education(Grant No.1685[2014]) the State Key Laboratory of Ocean Engineering(Shanghai Jiao Tong University)(Grant No.1312) China
关键词 rotational oscillation cylinder PIV frequency ratio wake flow pattern time-averaged flow field rotational oscillation cylinder, PIV, frequency ratio, wake flow pattern, time-averaged flow field
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部