摘要
镓回收工艺流程中的液体样品经预处理后采用时间分辨紫外脉冲荧光标准加入法测定铀含量。方法最低检出限为0.1μg·mL-1,测定结果相对标准偏差为2.7%,与ICP-MS法比对结果吻合。方法响应速度快,操作简单,适合镓回收工艺流程中微量铀的快速检测。
A new method was established to detect the trace uranium in gallium bearing solution in Bayer alumina hydrometallurgy by adding standard Time-Resolved UV-Induced Fluorescence. The LOD of the method is 0. 1 μg · mL- 1, and a RSD o5 2. 7% was achieved by ten times determination o[ uranium of 4 μg· mL-1 in gallium bearded solution. The detecting results was in good agreement with that of ICP- MS. The method is fast, cheap and easy in operation, there for it is applicable for the rapid determina- tion of uranium in gallium recovery process and other mining & metallurgy technology.
作者
李伯平
郭冬发
董红军
许家伟
崔建勇
张正林
邓文军
谢胜凯
王铁健
王志龙
董晨
LI Boping GUO Dongfa DONG Hongjun XU Jiawei CUI Jianyong ZHANG Zhenglin DENG Wenjun XIE Shengkai WANG Tiejian WANG Zhilong DONG Chen(Beijing Research Institute of Uranium Geology, Beijing 100029, China China Aluminum Limited by Share Ltd Guangxi Branch, Pingguo, Guangsci 531499, China)
出处
《铀矿地质》
CAS
CSCD
2017年第5期308-313,共6页
Uranium Geology
基金
国家重大科学仪器设备开发专项项目(No.2012YQ250003)资助
关键词
时间分辨
紫外脉冲
荧光
铀
镓
time-resolution
UV-induce
fluorescence
uranium
gallium