600MW亚临界空冷机组电动给水泵改造方案探讨

Retrofit Schemes for the Electric Feed Pump of a 600MW Subcritical Air-cooling Unit
下载PDF
导出
摘要 为了提高600 MW亚临界空冷机组电动给水泵经济性,结合电动给水泵改汽动给水泵、液力耦合器改调速变频器这两种主要的给水泵改造技术路线,分别计算在不同改造方案下,机组对应不同负荷的改造效果。同时结合场地条件、负荷率、运行方式、投资等因素,针对不同的机组选择合适的改造方案。 To improve the economy of a 600 MW subcritical air-cooling unit driven by electric feed pumps, there are in total two main technical strategies. One way is to use steam feed pump instead of electric feed pump, the other is to adopt frequency conversion instead of fluid coupling. Retrofit effects of the unit at different loads were calculated respectively for both the strategies. Considering the area conditions, load rate, operation mode and investment factors, appropriate retrofit schemes were proposed for the electric feed pump in different units.
出处 《发电设备》 2017年第5期356-359,共4页 Power Equipment
关键词 亚临界空冷机组 给水泵汽轮机 液力耦合器 变频器 供电煤耗 Keywords.. subcritical air-cooling unit steam turbine for feed-water pump fluid coupling frequencyconverter coal consumption of power supply
  • 相关文献

参考文献4

二级参考文献9

  • 1王文斌.液力传动[M].北京:机械工业出版社2007:15-19.
  • 2刘应城.液力偶合器实用手册[M].北京:化学工业出版社,2008:24-34,4246,301-317.
  • 3陈冬生,董光源,冯才.液压传动与液力传动[M].北京:水利电力出版社,1994:5-7.
  • 4齐任贤.液压传动与液力传动[M].北京:冶金工业出版社,1987:20-23.
  • 5匡襄.液力传动[M].北京:机械工业出版社1987:8-10.
  • 6李芳民.工程机械液压与液力传动[M].北京:人民交通出版社,2002:13-14.
  • 7国家发展和改革委员会.DL/T1078--2007表面式凝汽器运行性能试验规程[S].北京:中国电力出版社,2008.
  • 8俞兴超.1000MW超超临界火电机组给水泵配置及分析[J].华东电力,2008,36(9):90-94. 被引量:23
  • 9沈坚,黄兆华,陈昕,王建梅,张春琳,冯俊涛.1000MW火电机组给水泵组配置对机组运行的影响[J].节能,2013,32(1):39-42. 被引量:4