摘要
目的验证某型飞机从万米高空俯冲降落直至着陆滑跑过程中,在经历了环境温度从-55℃到常温快速剧烈变化后起落架性能的改变。方法依据起落架落震试验要求,进行起落架高低温环境模拟技术研究。结果综合考虑试验技术指标、试验件结构尺寸和试验场地限制,成功研制了专用的起落架高低温环境模拟设备。结论为研究起落架缓冲器内敏感参数与温度的变化规律和起落架结构性能提供了验证手段。
Objective To verify the performance change of a landing gear after a rapid and severe change of ambient temperature from-55 ℃ to normal temperature in the progress of aircraft diving form high altitude to landing and taxiing. MethodsHigh and low temperature environment simulation techniques for aircraft landing gear were researched according to requirements on drop test of landing gear. Results Special high and low temperature simulation equipment for landing gear was successfully developed in view of indicators on test techniques and restrictions on structural size of test piece and test site. Conclusion It provides a method for verifying change rules of sensitive parameters and temperature in the buffer of the landing gear and the structural performance of the landing gear.
出处
《装备环境工程》
CAS
2017年第8期34-38,共5页
Equipment Environmental Engineering
关键词
起落架
落震试验
高低温环境模拟设备
landing gear
drop test
high and low temperature environment simulating units