大物品放射性污染检测仪称重单元部分面板受力分析

Large Items Radioactive Contamination Detector Weighing Unit Part Panel Stress Analysis
下载PDF
导出
摘要 针对大物品放射性污染检测仪称重单元面板变形,引起重力传感器失效的问题。从称重单元部分面板受力情况、实际使用材料,安装定位等问题入手进行改进设计。基于SOLIDWORKS中的simulation分析模块,对称重单元进行有限元分析。分析结果表明,称重单元的结构设计满足指标要求,能为相关设计提供借鉴。 For large items radioactive contamination detector weighing unit panel deformation,cause gravity sensor failure problems. From the weighing unit part panel stress distribution, the actual use of material,installation position and other problems to improve the design. Based on the simul ltion analysis modules of SOLIDWORKS,finite element analysis was carried out on the weighing unit. The analysis results show that the strm ture design of the weighing unit meets the demand of indicators, can offer reference for relevant design.
作者 屈驰 温江波
出处 《机电产品开发与创新》 2017年第4期111-112,共2页 Development & Innovation of Machinery & Electrical Products
关键词 称重单元 变形 分析 改进 weighing unit deformation analysis improve