期刊文献+

经胸心脏超声评估儿童容量反应性的研究进展 被引量:1

Research Progress of Fluid Responsiveness in Children with Transthoracic Echocardiography Evaluation
下载PDF
导出
摘要 液体治疗是临床广泛应用的基本治疗措施。精确评估容量反应性有助于预测液体治疗疗效,避免无效或具有风险的液体治疗。随着近年的不断研究,经胸心脏超声应用范围逐步扩大,深入ICU、麻醉科、急诊科等多学科领域。经胸心脏超声应用于容量反应性的评估,具有无创、便捷、准确等优势。儿童与成人在生理方面存在巨大差异,循环系统发育不完善,输液不当极易导致左心衰、肺水肿等严重并发症。本文将经胸心脏超声评估儿童容量反应性的研究进展做一概述。 Liquid therapy is the basic treatment of clinical practice. Accurate assessment of fluid responsiveness helps to predict the efficacy of liquid therapy and avoid ineffective or risky treatment. With the continuous research in recent years,the application of transthoracic ultrasound has been widely applied to ICU,anesthesiology,emergency department and other disciplines. It has great clinical application value with the advantages of noninvasiveness,convenience and accuracy. There is a huge difference between children and adults in physiology. For children,,fluid infusion may easier lead to left heart failure,pulmonary edema and other serious complications with the immature circulatory system. Here we reviewed the research progress of the application of transthoracic echocardiography in predicting fluid responsiveness in children.
作者 李艺 叶军明
出处 《赣南医学院学报》 2017年第4期653-658,共6页 JOURNAL OF GANNAN MEDICAL UNIVERSITY
基金 2016年赣州市指导性科技计划项目(编号:GZ2016ZSF212)
关键词 经胸心脏超声 儿童 容量反应性 transthoracic Echocardiography children fluid responsiveness
  • 相关文献

参考文献4

二级参考文献96

  • 1俞建峰,顾勤,刘宁.不同呼吸末正压对机械通气患者心脏前负荷影响及前负荷预测性指标研究[J].中国血液流变学杂志,2008,18(2):237-239. 被引量:12
  • 2Monnet X,Anguel N,Naudin B. Arterial pressure-based cardiac output in septic patients:different accuracy of pulse contour and uncalibrated pressure waveform devices[J].{H}CRITICAL CARE,2010,(03):R109.
  • 3Yamashita K,Nishiyama T,Yokoyama T. The effects of vasodilation on cardiac output measured by PiCCO[J].{H}Journal of Cardiothoracic and Vascular Anesthesia,2008,(05):688-692.
  • 4Levy MM,Fink MP,Marshall JC. 2001 SCCM/ESICM/ ACCP / ATS / SIS International Sepsis Definitions Conference[J].{H}CRITICAL CARE MEDICINE,2003,(04):1250-1256.
  • 5Biais M,Vidil L,Sarrabay P. Changes in stroke volume induced by passive leg raising in spontaneously breathing patients:comparison between echocardiography and Vigileo/FloTrac device[J].{H}CRITICAL CARE,2009,(06):R195.
  • 6Lafanechère A,Pène F,Goulenok C. Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients[J].{H}CRITICAL CARE,2006,(05):R132.
  • 7Préau S,Saulnier F,Dewavrin F. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis[J].{H}CRITICAL CARE MEDICINE,2010,(03):819-825.
  • 8Machare-Delgado E,Decaro M,Marik PE. Inferior vena cava variation compared to pulse contour analysis as predictors of fluid responsiveness:a prospective cohort study[J].{H}Journal of Intensive Care Medicine,2011,(02):116-124.
  • 9Thiel SW,Kollef MH,Isakow W. Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients:an observational cohort study[J].{H}CRITICAL CARE,2009,(04):R111.
  • 10Reuse C,Vincent JL,Pinsky MR. Measurements of right ventricular volumes during fluid challenge[J].{H}CHEST,1990,(06):1450-1454.

共引文献78