摘要 采用预埋传感器阻尼振动法对钢筋浆锚搭接灌浆过程中的施工质量进行了检测,采用冲击回波法和X射线法分别对波纹管约束和螺旋箍筋约束的钢筋浆锚搭接试件的灌浆密实度进行了检测。结果表明:预埋传感器阻尼振动法对灌浆施工过程的灌浆密实度的判断较为可靠;冲击回波法可以定性地发现灌浆不密实的情况,但对灌浆段和非灌浆段的界面判断不够准确;X射线法可以较清楚地判定单排孔道内部灌浆段和非灌浆段的界面,并建议了适当的检测参数,但其有效检测时的试件厚度有明显限制。现场检测时,可以综合应用预埋传感器阻尼振动法和X射线法,分别进行灌浆密实度的过程控制和事后检验,以有效提升灌浆质量。 The grouting compactness of the rebar lapping in grout-filled hole during the grouting process were tested by damping vibration method with embedded sensors. The grouting compactness of the rebar connection with corrugated pipe constraints and spiral stirrups constraints were tested by impact-echo method and X-ray method respectively. The experimental results show that the damping vibration method with embedded sensors was reliable in the judgment of grouting compactness during the grouting process. The impact-echo method was able to give a qualitative judgment for grouting compactness, but the interface between grouting and non-grouting could not be reflected accurately. The X-ray method could clearly detect the interface between grouting and non-grouting for the single row connection and the appropriate testing parameters for X-ray method were suggested. The thickness of specimen strongly affected the test results, and it should be restricted in the X-ray test. In order to effectively improve the quality of grouting, it is recommended that the integrated application of the damping vibration method with embedded sensors for grouting process control and the X-ray method for back testing.
出处 《施工技术》 CAS 北大核心 2017年第17期10-14,共5页 Construction Technology
基金 上海市科委课题(16DZ1201805)
关键词 装配式结构 钢筋浆锚搭接 密实度 X射线法 阻尼振动法 冲击回波法 prefabricated construction rebar lapping in grout-filled hole compactness X-ray method damping vibration method impact-echo method
  • 相关文献

参考文献3

二级参考文献20

  • 1中国建筑股份有限公司,中建三局建设工程股份有限公司.JGJ169-2009清水混凝土应用技术规程[s].北京:中国建筑工业出版社,2009.
  • 2建筑施工手册(4版)[M].北京:中国建筑工业出版社,2003.
  • 3PCa技术研究会.プレキャストコンリ一ト技术マニヱアル[M].东京:株式会社彰国社,2000:38-47.
  • 4渡边邦夫,中野清司.知ちれざるPC建筑[M].东京:株式会社建筑技术,2004:152-171.
  • 5鲤田和夫.最新建篥施工[M].东京:技报堂出版株式会社.2008:82-83.
  • 6PARK R, PAULY T. Reinforced concrete structures [ M ]. New York : John Wiley and Sons Ins, 1982:236 - 296.
  • 7MAGNUSSON J. Bond and anchorage of ribbed bars in high-strength concrete [ D ]. Goteborg, Sweden : Division of Concrete Structures, Dept of Structural Engineering, Chalmers University of Technology,2000.
  • 8宋玉普 赵国藩.钢筋与混凝土之问的粘结滑移性能研究.大连工学院学报,1987,.
  • 9NAMMUR G,Jr, NAAMAN A E. Bond stress model for fiber reinforced concrete based on bond stress-slip rela- tionship [ J i- ACI Materials, 1989,86 ( 1 ) :45 - 57.
  • 10LUTZ L A. Analysis of stresses in concrete near a rein- forcing bar due to bond and transverse cracking [ J ]. ACI Journal, 1970,67 (10) :778 - 787.

共引文献177

同被引文献87

引证文献12

二级引证文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部