摘要
锅炉长时间低水位运行,停炉后又瞬间进水。为确认锅炉的损伤情况,对锅炉进行了检测并进行了分析。
Water flowed into a boiler which had been operated at low water level for a long time just after it shut down. In order to confirm the damage of the boiler, the boiler was tested and analyzed.
出处
《氯碱工业》
CAS
2017年第9期41-43,共3页
Chlor-Alkali Industry
关键词
氢气锅炉
材质
硬度
金相组织
拉伸强度
检测
分析
hydrogen boiler
material
hardness
. metallographical structure
tensile strength
detection
analysis