摘要
The Shanghai Advanced Proton Therapy facility employs third-integer slow extraction. In order to achieve accurate treatment, high-quality spill is needed. Therefore,parameters that may affect slow extraction should be investigated by simulation. A computer model of the synchrotron operation slow extraction was constructed with MATLAB~. By simulating the motion of the circulating protons, we could quantify the influence of machine and initial beam parameters on properties of the extracted beam, such as ripple, uniformity, stability, on-and off-time of the spill and spill width in the synchrotron.Suitable design parameters including the horizontal tunes,power supply ripple, longitudinal RF cavity voltage, RFKO and the chromaticities were determined.
The Shanghai Advanced Proton Therapy facility employs third-integer slow extraction. In order to achieve accurate treatment, high-quality spill is needed. Therefore, parameters that may affect slow extraction should be investigated by simulation. A computer model of the syn- chrotron operation slow extraction was constructed with MATLAB~. By simulating the motion of the circulating protons, we could quantify the influence of machine and initial beam parameters on properties of the extracted beam, such as ripple, uniformity, stability, on- and off-time of the spill and spill width in the synchrotron. Suitable design parameters including the horizontal tunes, power supply ripple, longitudinal RF cavity voltage, RF- KO and the chromaticities were determined.
基金
supported by the Youth Innovation Promotion Association of Chinese Academy of Sciences(No.20150210)