摘要
为了准确测定含稀土磷矿石中钛的含量,采用两种溶样方法对磷矿进行处理,用电感耦合等离子体发射光谱(ICP-OES)法对磷矿中钛进行测定。实验表明,不进行基体匹配的标准曲线法不适合磷矿中钛的分析,采用基体匹配的标准曲线法时又难以制得与其各组分含量相似的校准溶液。用能有效消除样品本身基体干扰的标准加入法进行测定,分析结果的相对标准偏差小于2.0%,碱熔法的加标回收率为98.48%,酸溶法的加标回收率为104.4%,检测结果可靠,适合于磷矿中钛的分析。
To accurately determine the content of titanium in the phosphate ores, two dissolution methods were adopted to prepare the samples. The content was determined by ICP-OES. The experimental results showed that the standard curve method without matrix matching was not suitable for the determination of titanium in the phosphate ores, while the method with matrix matching was difficult to match the calibration solution with the content of each component. Standard addition method was used to analyze the samples and the matrix interference was eliminated effectively. The relative standard deviation for the determination of titanium was less than 2%. The recoveries of alkali fusion method and acid melting method were 98. 48% , and 98. 48% respectively.
出处
《中国无机分析化学》
CAS
2017年第3期29-32,共4页
Chinese Journal of Inorganic Analytical Chemistry
基金
国家级大学生创新项目(201610668019)
毕节市煤磷化工工程技术中心(毕科合字[2015]1号)平台资助