期刊文献+

直立锁边屋面抗风性能有限元分析 被引量:14

FINITE ELEMENT ANALYSIS OF WIND-RESISTANCE PERFORMANCE OF STANDING SEAM ROOF
下载PDF
导出
摘要 直立锁边屋面系统因其具有防水性能好、强度比较高等特点而广泛的应用在我国建筑结构中,但是由于目前我国还没有完善的规范体系,所以在使用的过程中仍然发生抗风揭能力不足而导致屋面板被掀开的现象,严重危害人们的生命和财产安全。通过试验,利用有限元分析软件MIDAS进行模拟,通过对边界条件合理的假定,探求影响直立锁边屋面系统抗风揭性能的影响因素。结果表明:减小檩距、增加板厚和板宽等形式可以增加屋面板的抗风揭性能;同时找到了各个影响因素对金属屋面板抗风揭性能影响的敏感区域。 Standing seam roof system has been widely used in buildings on account of excellent waterproof performance and high strength. However,there is no perfect standard in China at present,so there is still an issue that the deficiency of wind loading rating in use,and it also threatens people's lives and propery at the same time. Based on the professional experiments,the finite element analysis software MIDAS was used to conduct the simulation,and through the reasonably constraint to boundary conditions,the influence factors of the waterproof performance in standing seam roof system were investigated. The results showed that the wind-resistance performance could be improved by decreasing the distance of the purlin spacing and increasing the thickness and width of the board. Meanwhile,the sensitive area of the various influence factors influencing the metal roofing boards were obtained.
出处 《钢结构》 北大核心 2017年第8期72-76,共5页 Steel Construction
关键词 金属屋面系统 直立锁边 风荷载 抗风揭性能 数值模拟 metal roofing system standing seam wind load wind resistance performance numerical simulation
  • 相关文献

参考文献5

二级参考文献29

  • 1蔡昭昀.我国金属屋面工程发展现状[J].中国建筑防水,2010(3):19-22. 被引量:13
  • 2孙成疆.直立锁缝金属屋面系统在模拟极端暴风工况下抗风揭能力测试和分析[J].建筑结构,2011,41(S1):1438-1442. 被引量:23
  • 3JCJ255-2012采光顶与金属屋面工程技术规程[S].北京:中国建筑工业出版社,2012.
  • 4[日]建筑图解事典编集合委员会.建筑结构与构造[M].刘茂榆,译.北京:中国建筑工业出版社,2007.
  • 5B.J Vickery, P. N. Georgiou. A Simplified Approach to the Determimation of the Influence of Internal Pressure on the Dynamics of Large Span Roofs; [J] Wind Eng.Ind. Areodyn,1991, (38) ,357-369.
  • 6R.N.Sharma, P.J.Richards;The Effect of Flexibility on Internal Pressure Fluctuations ; [J] .Wind Eng.Ind.Aerodyn, 1997, (72) ,175-186.
  • 7UL580-2006 Test for Uplift Resistance of Roof Assemblies [S] .
  • 8澳门金属结构协会等.CIS-MRS-01-04:2011装配式金属屋面系统行业标准[S],2011.
  • 9CSA A123.21-10 Standard test method for the dynamic wind uplift resistance of membrane-roofing systems [S] .
  • 10清华大学建筑玻璃与金属结构研究所.国家大剧院屋面板拉拔试验检测报告[R],2003.