摘要
当修建的地铁线路穿越江河、湖泊时,在进出水域的两端适当位置均需设置防淹门。为在防淹门区域灾害情况下保证列车与乘客的绝对安全,负责列车控制与安全防护的地铁信号系统必须与防淹门系统设置接口,实现列车控制与防淹门控制的联动功能,并保证各系统接口的安全可靠。为此,此文以杭州地铁4号线两车站所设防淹门为例,对与信号系统间所设接口电路的可靠性进行了分析与计算。
When the subway line across the river and lake,the flood gate should be installed in the proper position at both ends of inlet and outlet. In order to ensure the absolute safety of trains and passengers in the case of flood gate area disaster,the interface between the subway signal system for train control and safety protection and flood gate system must be set up to realize the linkage function of train control and anti flood door control. And that also can ensure safety and reliability of system interface. Therefore,taking the flood gate of two stations of Hangzhou Metro Line 4 as an example,the reliability of interface circuit between signal system and signal system is analyzed and calculated.
出处
《铁路工程技术与经济》
2017年第5期36-40,共5页
Railway Engineering Technology and Economy
基金
国家科技支撑计划(2015 BAG13B01)
下一代地铁车辆技术研究及示范应用
关键词
地铁
信号联锁系统
防淹门系统
接口电路
可靠性
Metro
Signal interlocking system
Flood gate system
Interface circuit
Reliability