分析了由变频器供电的永磁电动-发电机组转速异常波动的原因。根据机组中永磁发电机的结构特点和现场条件,提出了在不拆解发电机的情况下,对绕组匝间短路故障进行定位的方法。
Cause to result in the abnormal variation of rotating speed of the motor-generator set powered by frequency converter was analyzed. Based on the structural characteristics of PM generator in the set and site condition, the method to positioning inter-turn short-circuit-default in the condition not to disassemble the generator was presented.
出处
《电机技术》
2017年第4期50-51,55,共3页
Electrical Machinery Technology
关键词
变频器
永磁发电机组
转速波动
inverter
PM generator set
variation of rotating speed