期刊文献+

一种分体式燃气体积修正仪校准标准装置 被引量:1

A Separate Standard Facility for Gas-Volume Conversion Device
下载PDF
导出
摘要 阐述分体式燃气体积修正仪校准标准装置的研制目的和功能,探讨标准装置的硬件构成、软件功能和设计思路,介绍校准过程,估算标准装置的测量不确定度。该标准装置研发和使用为2型燃气体积修正仪的校准提供准确可靠的装置和方法。 The research purpose and function of separate standard facility for gas -volume conversion device are expounded. The hardware composition, software functions and design ideas of the standard device are discussed. The calibration process is introduced, and the measurement uncertainty of the standard device is esti- mated. The development and use of the standard device will provide accurate and reliable means and methods for the calibration of type 2 gas -volume conversion device.
作者 张涛 魏勇 籍瑞春 柴家凤 李曼曼 王勋 ZHANG Tao WEI Yong JI Ruichun CHAI Jiafeng LI Manman WANG Xun
出处 《煤气与热力》 2017年第9期24-28,33,共6页 Gas & Heat
关键词 计量 校准标准装置 燃气体积修正仪 不确定度 metrology standard facility gas - volume conversion device uncertainty
  • 相关文献

参考文献1

二级参考文献7

  • 1国家质量技术监督局.JJF1094--2002测量仪器特性评定[S].2002.
  • 2国家质量技术监督局.GB/T17747.1~3-2011天然气压缩因子的计算[S].2011.
  • 3国家质量技术监督局.GB/T27759--2011流量测量不确定度评定程序[S].2011.
  • 4北京市燃气集团有限责任公司北京市公用事业科学研究所.体积修正仪示值误差校准标准装置及使用方法:CN,201210333928.2[P].2012-12-26.
  • 5European Committee for Standardization. EN 12405:2002 Gas meters-Gas-volume electronic conversion devices [ S . 2002.
  • 6卢兆明,忻龙,胡伟欣.温度试验箱内部环境条件的不确定度要素分析[J].上海标准化,2010(6):24-29. 被引量:5
  • 7闫文灿,肖迪,徐明,陆玉城.移动式天然气计量标准装置不确定度评定[J].计量学报,2014,35(1):54-60. 被引量:5