摘要 目的建立测定甲硫氨酸维B1氯化钠注射液中甲硫氨酸含量的高效液相色谱(HPLC)法。方法采用COSMOSIL5 C18-MS-Ⅱ色谱柱(250 mm×4.6 mm,5μm);以水为流动相,流速为1.0 mL/min;柱温为30℃,检测波长为228 nm。结果甲硫氨酸质量浓度在70.94~638.46μg/mL范围内与峰面积线性关系良好(r=0.999 9),平均回收率为100.03%,RSD为0.86%(n=9)。结论该方法准确、简便、快速、重复性好,适用于甲硫氨酸维B1氯化钠注射液中甲硫氨酸的含量测定。 Objective To establish an HPLC method for content determination of methiouine in Methiouine in Methiouine-Vitamin B1 and Sodium Chloride Injection. Methods The COSMOSIL5 C18-MS-Ⅱ column( 250 mm × 4. 6 mm,5 μm) was performed,the mobile phase was water,the flow rate was 1. 0 mL/min,the temperature was set at 30 ℃,the detection wavelength was 228 nm. Results Methiouine showed a good linear in the concentration range of 70. 94-638. 46 μg/mL( r = 0. 999 9). The average recovery of methiouine was 100. 03%,and RSD was 0. 86%( n = 9). Conclusion The method is accurate,simple,rapid and reproducible,which can be used for the content determination of methiouine in Methiouine in Methiouine-Vitamin B1 and Sodium Chloride Injection.
作者 肖雷 许龙 Xiao Lei Xu Long(The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China 230022 Anhui Piom Pharmaceutical Co., Ltd., Hefei, Anhui, China 230022)
出处 《中国药业》 CAS 2017年第18期14-16,共3页 China Pharmaceuticals
关键词 高效液相色谱法 甲硫氨酸维B_1氯化钠注射液 甲硫氨酸 含量测定 HPLC Methiouine-Vitamin B_1 and Sodium Chloride Injection methiouine content determination