期刊文献+

一起因自动扶梯梯级缺失引发的人员伤害事故案例 被引量:1

A Case of Injury Caused by the Lack of Escalator Steps
下载PDF
导出
摘要 自动扶梯梯级缺失监测装置是国家安全标准GB 16899—2011的新增内容,主要是为了防止乘客踏入因梯级(踏板)缺失导致的缺口而造成被剪切或挤压的伤害。本文结合一起因梯级缺失引发的人员伤害事故案例,从人的不安全行为和设备的不安全状态两个方面,对事故的原因进行深入剖析;同时,从风险防控和技术法规两个层级,提出相应的预防措施,避免类似事故的再次发生。 The escalator step missing monitoring device is the new content of national security standard GB 16899—2011. The main purpose is to prevent passengers from entering the gap caused by the lack of steps, resulting in shearing or crushing injuries. Combining with a case of accidental injury caused by the lack of steps, from two aspects of human unsafe behavior and unsafe state of equipment, this article deeply analyzes the reasons of accident, and puts forward corresponding preventive measures from two levels of risk prevention and technical regulations, to avoid the recurrence of similar incidents.
作者 梁骁 施鸿均 黄文和 Liang Xiao Shi Hongjun Huang Wenhe(Shanghai Institute of Special Equipment Inspection Technical Research Shanghai 200333 Shanghai Elevator Joint Safety Technology Promotion Center Shanghai 201114)
出处 《中国特种设备安全》 2017年第8期81-83,共3页 China Special Equipment Safety
关键词 自动扶梯 梯级缺失监测装置 缺口 风险防控 预防措施 Escalator Step missing monitoring device Gap Risk prevention Preventive measures
  • 相关文献

参考文献4

二级参考文献3

  • 1国家技术监督局.自动扶梯和自动人行道的制造与安装安全规范[S].GB16899—1997.1997-07-02批准.
  • 2ARM Limited The ARM-THUMB Procedure Call Standard SWS ESPC [z] 0002 B-01 24 October, 2000.
  • 3倪明主.浅议自动扶梯与自动人行道梯级缺失保护[J].城市建设理论研究,2004,(23).

共引文献7

同被引文献4

引证文献1

二级引证文献3