摘要 针对风机变频改造后发生的膜片式联轴器膜片损坏故障问题,通过测试传动轴动态扭矩信号,将其作用到膜片上,计算得到膜片所承受的拉应力。试验发现,变频改造后风机在一定转速区间运行时,联轴器所承受的扭矩出现了大幅脉动,导致膜片承受的拉应力出现大幅波动,波动幅度超过平均值。根据膜片联轴器工作特点,采用局部应力-应变法计算脉动扭矩作用下膜片疲劳寿命。试验和计算结果表明,变频调速后风机传动轴上出现的扭矩脉动对膜片寿命的影响较大。扭矩脉动情况下,膜片疲劳强度不够,容易出现疲劳损伤。 The tensile stress of the membrane was calculated using the measured shaft dynamic torque signal for the analysis of the reason of membrane damage after the fan with variable frequency drive modification. Test result shows that large toque pulsation occurred on the coupling when the fan runs in certain speed zone. It causes large tensile stress pulsation of the membrane thereafter. The amplitude of the pulsation stress is larger than that of the mean stress. The local stress-strain method was used to calculate membrane fatigue life according to the work condition of the membrane coupling. It is found that there is large influence of the pulsation torque on the fatigue life of membrane. Membrane fatigue strength is not enough in case of torque with large pulsation. The membrane is easy to be damaged.
作者 王青华 李冬冬 冯波 李晓峰 茅冬春 许振锋 杨建刚 WANG Qing-hua LI Dong-dong FENG Bo LI Xiao-feng MAO Dong-chun XU Zhen-feng YANG Jian-gang(Shanghai Minghua Electric Power Technology Engineering Co., Ltd., Shanghai 200090, China Shanghai Caojing Electric Power Co., Ltd., Shanghai 201507,China National Engineering Research Center of Turbo Generator Vibration, Southeast University, Nanjing 210096, China)
出处 《煤矿机械》 2017年第9期151-153,共3页 Coal Mine Machinery
关键词 膜片联轴器 风机 疲劳寿命 laminated membrane coupling fan fatigue life
  • 相关文献

参考文献3

二级参考文献11

共引文献26

同被引文献52

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部